Order Code: 24258098.82
Category: General Lab Equipment V
Wet cooling tower Principle of operation and characteristic variables of a wet cooling tower with forced ventilation Features • principle and characteristic variables of a wet cooling tower with forced ventilation • transparent, easily ...
Wet cooling tower
Principle of operation and characteristic variables of a wet cooling tower with forced ventilation
Features
• principle and characteristic variables of a wet cooling tower with forced ventilation
• transparent, easily interchangeable cooling column with wet deck surface
• 4 additional cooling columns available as accessory
Specification
• principle of a wet cooling tower with cooling column and forced ventilation
• interchangeable cooling columns with different wet deck surfaces available as accessories
• water circuit with pump, filter, valve and a nozzle as atomiser
• three-stage heater with thermostat for water heating
• radial fan for forced ventilation
• throttle valve to adjust the air flow
• display of temperature, differential pressure, flow rate and humidity
• software for data acquisition via USB under Windows 8.1, 10
Technical data
Cooling column
• specific surface of the wet deck surface: 110m2/m3
• cross-section: 150x150mm
Volumetric air flow measurement via orifice: Ø 80mm
Heater, adjustable in three stages:
• 500W
• 1000W
• 1500W
Thermostat: switches off at 50°C
Fan
• power consumption: 250W
• max. pressure difference: 4,3mbar
• max. volumetric flow rate: 13m3/min
Pump
• max. head: 70m
• max. flow rate: 100L/h
Tank for additional water: 4,2L
Measuring ranges
• differential pressure: 0...10mbar (air)
• flow rate: 12...360L/h (water)
• temperature: 2x 0...50°C, 3x 0...100°C
• rel. humidity: 10...100%
230V, 50Hz, 1 phase