Order Code: 24258213.1
Category: General Lab Equipment V
Components: The Western blotting system has two components including PAGE (1 set) and Gel imaging (1 set) systems. PAGE System: It include all accessories necessary for PAGE protein analysis; Simple and secure lock...
Components: The Western blotting system has two components including PAGE (1 set) and Gel imaging (1 set) systems.
PAGE System:
It include all accessories necessary for PAGE protein analysis; Simple and secure locking system to prevents buffer leakage.
Inner electrophoresis chamber with electrodes (with side clip for gel holder 2x): ≥ 1 Pcs.
Inner electrophoresis chamber without electrodes (with side clip for gel holder 2x): ≥ 1 Pcs.
U sealing strip long for 10 x 10 cm gels: ≥ 4 Pcs.
U sealing strip short for 10 x 8 cm gel: ≥ 4 Pcs.
U sealing strip Fast Gene (10 x 8 cm): ≥4 Pcs.
Plastic dummy cassette short (10 x 8 cm): 1 Pcs.
Plastic dummy cassette long: ≥1 Pcs.
Gel/blot chamber lid with electrodes (and power cable): ≥1 Pcs.
Fast Gene® Gel/Blot chamber tank (PG05): 1 Pcs.
Gel shovel: ≥5 Pcs.
Comb 1 mm with 10 wells: ≥ 5 Pcs
Comb 1 mm with 15 wells: ≥ 5 Pcs
Glass spacer long 1 mm: ≥ 5 Pcs.
Glass plates short: ≥10 Pcs.
Gel casting base: ≥4 Pcs.
Gel casting clip: ≥ 4 Pcs.
Sealing gaskets: ≥ 5 Pcs.
Glass plate holder: ≥1 Pcs.
Tube holder: ≥1 Pcs.
Comb 0.75 to .80 mm with 10 wells: ≥5 pcs.
Comb 0.75 to .80 mm with 15 wells: ≥5 pcs.
Glass spacer long 0.75 to 0.80 mm: ≥5 pcs.
Glass plate short :10 x
Blot frame with electrodes: ≥ 1 Pcs
Blot connector: ≥ 2 Pcs
Blot sponge: ≥ 5 Pcs
Blot cool pack: ≥ 2 Pcs
Power supply: Microprocessor controller or advanced technology;
Output voltage: Step 01: 10 - 300V / 1V
Step 02: 10 - 300V / 1V
Output current: Step 01:10 - 400mA / 1mA
Step 02: 10 - 400mA / 1mA
Watt: ≤60Watt.
Output type: Constant voltage or constant current
Terminal pairs:≥ 02 pairs
Timer: more than 995 minutes with alarm system.
Combs, blots and power systems should be adjustable with offered main component.
Gel imaging system:
Camera sensor type: Scientific-grade CMOS or advanced technology.
Image resolution: ≥ 20 MPixel (≥5400 px x ≥3640 px)
Image format: JPEG, TIFF, PNG, BMP or advanced.
Exposure time: 13 µs to 10 sec or better.
Light sources: Blue/Green LED, White LED light
Trans illuminated area: 26 cm x 21 cm or better.
Blue/Green LED light: 470-520 nm.
Dimensions (H x D x W): ≥ 50 cm x 44 cm x 36 cm
Weight: Maximum 22 kg.
Display: ≥13'' full HD touchscreen or advanced technology
Display resolution: 1920 x 1080 or advanced
Internal storage: ≥128 GB
Connections: LAN, 3x USB 3.0 or advanced
Software: FAS-X imaging software or advanced technology
Rated voltage: 100-240 V, 50 / 60 Hz
Power adapter 24 V, 6 A
Material: Coated aluminum or advanced tested materials.
Filter: Amber goggles or advanced technology.
Status LED or advanced technology: It have Installation in the front.