Order Code: 24258298.2
Category: General Lab Equipment V
Determination of Vicat softening temperature (VST), heat deflection temperature (HDT) and creep behavior under flexural load for thermoplastics, hard rubber and fiber reinforce thermosets No. of measuring stations 3 Temper...
Determination of Vicat softening temperature (VST), heat deflection temperature (HDT) and creep behavior under flexural load for thermoplastics, hard rubber and fiber reinforce thermosets
No. of measuring stations 3
Temperature range +20 to +300 °C
Re-cooling PC-controlled via solenoid valve
Oil capacity, approx. 19.9
Height x width x depth 500 x 440 x 600 mm
Weight (without accessories), approx. 30 kg
Display accuracy at 250 °C ±0.5 °C
Spatial temperature gradient ±0.1 °C
Temperature measurement resolution 0.1 °C
Temperature sensor Oil-bath temperature is measured by 1 temperature sensor.
Heating rate 50, 120 or freely adjustable K/h
Displacement measurement with digital measuring transducers: resolution 0.001 mm
display accuracy ±0.01 mm
POWER CONNECTION: mains voltage 230/240 V, mains frequency 50/60 Hz& power rating 3460 W
PC INTERFACES REQUIRED: 1x for temperature channel (RS) & 1x for displacement channel (RS)
SPECIMEN DATA:
VST specimen dimensions, max. 10 x 6.5 x 10 mm
HDT specimen dimensions, max. 13 x 15 x 130 mm
HDT spans 64, 100 and 101.6 mm
ACCESSORIES REQUIRED
Vicat flat-ended needle - 3No.
Weight set for Vicat - 10N and 50N as per ISO 306 and ASTM - 3No.
Die for HDT - 3No.
HDT calibration and centering tool for alignment of the HDT die - 1x required
Weight set for HDT
HDT weight set, ISO 75-2 flatwise - For specimen size 4 x 10 mm (thickness x width ± 0.05 mm) and 80 mm length (± 2 mm), for flexural stresses of 1.8, 0.45 or 8 MPa. Adherence to specimen dimensions within ± 0.05 mm
HDT weight set, ISO 75-2 edgewise - For specimen size 10 x 4 mm (thickness x width ± 0.05 mm) and 120 mm length (± 10 mm), for flexural stresses of 1.8, 0.45 or 8 MPa. Adherence to specimen dimensions within ± 0.05 mm.
HDT weight set as per ASM D648 Methods A and B - For specimen size 3.175 x 12.7 mm (thickness x width), for flexural stresses of 1.82 / 0.455 MPa
HDT weight set as per ASM D648 Methods A and B - For specimen size 6.35 x 12.7 mm (thickness x width), for flexural stresses of 1.82 / 0.455 MPa
Calibration set for HDT/Vicat measurement transducer.
Universal set of weights for HDT/Vicat test standards - 1No. Required
Heat-transfer fluid for HDT/Vicat - 10 liters
Specimen cutters for Vicat for dimensioning Vicat specimens, with stop for specimen length of 10 mm