Transformer Study System With PC Interface

Order Code: 21225345.2

Category: General Lab Equipment I

Transformer Lab is an elite training system for the Electrical laboratories. The product helps you to get fully acquainted with the basic concepts and functioning of a Single Phase Transformer. The product is represented in such an easy way that e...



SPECIFICATION

  • Transformer Lab is an elite training system for the Electrical laboratories. The product helps you to get fully acquainted with the basic concepts and functioning of a Single Phase Transformer. The product is represented in such an easy way that each test can be studied differently in proper sequence. The Lab practically expertise you in exercises like Polarity, Turns Ratio, Transformation Ratio, Iron Loss, Copper Loss, Efficiency etc. The vast scope of learning makes the subject easily and completely understandable. Single Phase Trans

Features 

  • Inbuilt Single Phase Variac 
  • Equipped with Supply Indication Lamp 
  • Facility to use Fixed and Variable Load 
  • Control board consist of high grade FRP material to provide utmost safety to the users 
  • Terminals provided to use the optional externally 
  • Designed by considering all the safety  standards 
  • Diagrammatic representation for the ease of connections 
  • Flexibility to configure Step-up, Step-down and Isolation Transformer 
  • Exclusive and Compact Design 
  • Product Tutorial (CD) Scope of Learning 
  • Study of Transformation Ratio in a Single Phase Transformer 
  • Study of Polarity Test in a Single Phase Transformer • Study of Open Circuit Test in a Single Phase Transformer 
  • Study of Short Circuit Test in a Single Phase Transformer 
  • Study of Load Test and correspondingly determine the Efficiency and Voltage Regulation in a Single Phase Transformer Technical Specifications Mains Supply : Single Phase, 230V AC ±10%, 50Hz Single Phase Transformer Rating : 1kVA Primary Voltage : 0-125V, 0-125V Secondary Voltage : 0-125V, 0-125V Rated Current : 4A Single Phase Auto Transformer Primary Voltage : 230V Secondary Voltage : 0-270V Rated Current : 5A Digital Meters Used AC Voltmeter : 450V (2nos.) AC Ammeter : 5A (2nos.) Wattmeter : 1500W MCB (SP) : 6A 

Electrical Data Acquisition System 

  • It is a versatile solution that allows high quality measurements for all Electrical Parameters and is suited for all types of Engineering Laboratories. Electrical Data Acquisition System Provides wireless measurements of Single and Three Phase AC as well as DC Parameters measurements with high  accuracy.  Electrical Data Acquisition System 
  • includes three inputs each for Voltage and Current, two inputs each for DC Voltage and DC Current to measure an entire Three Phase Parameters and DC Parameters such as AC and DC Voltage, AC and DC Current, Active Power, Reactive Power, Apparent Power, Power Factor, Frequency, etc. along with Over Load Protection Indicators and buzzer at the same time. All these parameters will be displayed on the PC Software screen provided with the product. Electrical Data Acquisition System is compatible for three phase/three wire and three phase/four wire configurations. User can also plot a real time graph between any of these parameters on computer through the facility of wireless connectivity. Features 
  1. Electrical Data Acquisition System is compatible for Motors Up to 3HP 
  2. Real Time monitoring of electrical parameters using computer Interface Software 
  3. Curve can be plotted between any of the two electrical parameters along with its calculation done on computer 
  4. Facility to store plotting curve reading for further reference 
  5. Microcontroller based accurate and reliable design 
  6. Singe Phase Parameters Measurement - 3 AC Voltage Inputs - 3 AC Current Inputs Corresponding Active Power, Reactive Power, Apparent Power, Frequency, Power Factor and Angle - 2 DC voltage Inputs 
  7. Three Phase Parameters Measurement - Line to Neutral Voltage - Line to Line Voltage - Line Current - Active Power - Reactive Power - Apparent Power - Frequency - Power Factor 
  8. CT is used as Current Transducer 
  9. Fully isolated measurement Real Time monitoring of electrical parameters using computer interface software Electrical Data Acquisition System Subject to change - Version 2.0 Wireless connectivity with computer Speed Measurement Device Acquisitioyste0A Technical Specifications Communication Frequency : 2.4GHz RF Power : 1mWatt Range : 10Mtr. Measurement Ranges AC Voltage Range : 25-450Vrms, accuracy ±1% AC Current Range : 0.20-10Amp, accuracy ±1% DC Voltage Range : 25-300Vrms, accuracy ±1% DC Current Range : 0.20-15Amp, accuracy ±1% Frequency : 45-55Hz, accuracy ±0.5Hz Active Power : 50-3000Watts, accuracy ±2% Reactive Power : 50-3000Watts, accuracy ±2% Apparent Power : 50-3000Watts, accuracy ±2% Power Factor : 0.30 to 0.99 both Lead and Lag, accuracy ±3º Electrical Speed : Up to 2500 RPM Torque : 0 - 25 N-m Auxiliary Supply : 230V AC± 10%, 50Hz 
     

Enquiry Form