Transformer Experiment Trainer

Order Code: 18193308.2.6

Category: General Lab Equipment III

Measuring Coil Resistance of Transformer. Saturation curve and voltage ratio of Transformer. Impedance of Transformer. Current Ratio and Impedance of Transformer. Voltage regulation curve of transformer. Polarity of Transformer. The No...



SPECIFICATION

  1. Measuring Coil Resistance of Transformer.
  2. Saturation curve and voltage ratio of Transformer.
  3. Impedance of Transformer.
  4. Current Ratio and Impedance of Transformer.
  5. Voltage regulation curve of transformer.
  6. Polarity of Transformer.
  7. The No-load experiment of a single-phase Transformer.
  8. Short experiment of a single-phase Transformer.
  9. Load experiment of a single-phase Transformer.
  10. Parallel operation experiment of a single-phase transformer.
  11. Three phase connection experiment of single phase transformer.
  12. V connection practice experiment of single phase transformer.
  13. - The No-load experiment of a three-phase transformer.
  14. Short experiment of a three phase Transformer. - Load experiment of a three phase Transformer. Specification:
  15. Control Board
    1. 1Phase Transformer 300VA: min. 3EA
    2. Primary: 0/110/220/380V
    3. Secondary: 0 / 110 / 220 / 380V
    4. AC Voltage Meter: min. 3EA
    5. 150V: min. 2EA
    6. 300V: min. 2EA
    7. 600V: min. 2EA
    8. AC Ampere Meter
    9. 5A: min. 2EA
    10. 10A: min. 2EA
    11. 15A: min. 2EA
    12. Circuit Protector: min. 5EA
    13. MCCB 30AF, 10AT: min. 2 EA
    14. Toggle Switch: min. 9 EA
    15. Style: Steel, Potable Type;
  16. Warranty: min. 01(One) Year supported by performance security. Beyond 01(One) year manufacturer warranty applicable. In that case supplier should provide warranty card/manufacturer document prior to expiration of performance security.
  17. Original or Color Printed Catalogue/Brochure- [To be submitted by the bidder] User manual — [To be submitted on delivery by the bidder]
  18. Rated Current: min. 0.42A
  19. Rated Speed: min. 3300 rpm
  20. Rated Power: min. 92.4 W
  21. Motor Outside Shaft Length: min. 40mm DC Shunt wound motor
  22. Full Transparent min. 6mm Thickness Fiber/Acrylic Body
  23. 4mm safety jack Connection facility Rated input Voltage: min. 220 V DC Rated input Current: min. 0.7Amp Shunt field Current: min. 0.10Amp Armature Current: min. 0.60 Amp Rated Speed: min. 7000rpm
  24. Rated Power: min. 154W
  25. Motor Outside Shaft Length: min. 40mm DC Series wound motor
  26. Full Transparent 6mm Thickness Fiber/Acrylic Body
  27. 4mm safety jack Connection facility Rated Voltage: min. 100 V DC Rated Current: min. 0.41A
  28. Rated Speed: min. 6600 rpm
  29. Rated Power: min. 41W
  30. Motor Outside Shaft Length: min. 40mm DC Compound wound motor
  31. Full Transparent 6mm Thickness Fiber/Acrylic Body
  32. 4mm safety jack Connection facility Motor Outside Shaft Length: min. 45mm Short Shunt:
  33. Rated Voltage: min. 220V DC
  34. Rated Current: min. 0.125A
  35. Armature Current 0.055
  36. Shunt Current: min. 0.07
  37. Rated Speed: min. 1100 rpm
  38. Rated Power: min. 15W
  39. Long Shunt:
  40. Rated Input Voltage: min. 220V DC Rated Input Current: min. 0.25A Rated Speed: min. 2000 rpm
  41. Rated Power: min. 30W
  42. Universal motor
  43. Full Transparent 6mm Thickness Fiber/Acrylic Body
  44. 4mm safety jack Connection facility Rated Input Voltage: min. 120 V AC/DC Rated Input Current: min. 1.0 AC/DC Rated Speed: min. 8400 rpm (AC)
  45. Rated Speed: min. 10000 rpm (DC) Rated Power: min. 120W
  46. Motor Outside Shaft Length: min. 40mm Three Phase Induction motor (Y-Connection)
  47. Full Transparent 6mm Thickness Fiber/Acrylic Body
  48. 4mm safety jack Connection facility Rated Input Voltage: min. 400 V AC Rated Input Current: min. 0.085A Rated Speed: min. 1450 rpm
  49. Rated Power: min. 65W
  50. Motor Outside Shaft Length: min. 40mm
  51. Three Phase Rotor winding motor (Y-Connection)
  52. Full Transparent 6mm Thickness Fiber/Acrylic Body
  53. 4mm safety jack Connection facility Rated Input Voltage: min. 400 V AC Rotor Excitation Voltage: 50-100V (3-Phase Line; to Line)
  54. Rated Speed: min. 1500 rpm
  55. Motor Outside Shaft Length: min. 40mm Synchronous motor (Y-Connection)
  56. Full Transparent 6mm Thickness Fiber/Acrylic Body
  57. 4mm safety jack Connection facility Rated Input Voltage: min. 400 V AC Rated Input Current: min. 0.20A
  58. Installation, Testing & Commissioning should be provided by the Bidder 