Switchgear And Protection Trainer

Order Code: 22236247.4

Category: General Lab Equipment II

Specification Protective relay control station DC power supply :Input voltage: 240/415v AC, 3 phase Output voltage: 120V Output current: 5A  AC power supply: Input voltage: 240/415v AC, 3 phase Output voltage: 110V, 220V, 400V ...



SPECIFICATION

Specification

  • Protective relay control station
  • DC power supply :Input voltage: 240/415v AC, 3 phase
  • Output voltage: 120V
  • Output current: 5A 
  • AC power supply: Input voltage: 240/415v AC, 3 phase
  • Output voltage: 110V, 220V, 400V
  • Output current:  5A at 110V, 10A at 220V, 10A at 400V 
  • Current sensitivity relay module
  • Current metering range: 0.4 ~ 6A
  • Input current: 8A 
  • Hysteresis range: 5% to 50% of selected current
  • Output contact: 10A at 250VAC 
  • Operating voltage: 220V AC, 2.5A
  • Three phase under over/voltage relay module
  • Nominal input voltage: 69V or better option, line to neutral
  • Maximum input voltage: 120% of nominal input voltage
  • Under voltage set point range: 75% to 100% of nominal input voltage
  • Over voltage set point range: 100% to 125% of nominal input voltage
  • Hysteresis range: 1% to 15% of nominal input voltage
  • Output contact: 2 x SPDT, 5A at 240v AC
  • AC/DC volt sensitivity relay module
  • Voltage metering range: 40 to 600v
  • Maximum input voltage: 650v
  • Hysteresis range: 5% to 50% of selected metering range
  • Output contact: 8A at 250v AC
  • Operating voltage: 240v, AC
  • Under/over frequency relay module
  • Nominal frequency: 50Hz
  • Nominal input voltage:120v
  • Maximum input voltage: 120% 0f nominal input voltage
  • Frequency range: 40 t0 60 Hz
  • Synchronizing limit adjustment range: 0.1 to 3.0 Hz
  • Output contact: 2 x SPDT, 5A at 240v AC
  • Synchro-check relay module 
  • Nominal input voltage:120v
  • Minimum input voltage: 70% of nominal input voltage
  • Maximum input voltage: 130% of nominal input voltage
  • Frequency range: 45 to 65 Hz
  • Synchronizing limit adjustment range: 10% to 30% of nominal input voltage
  • Phase balance/sequence relay module 
  • Nominal input voltage: 120v, line to line
  • Minimum input voltage: 120% of nominal input voltage 
  • Unbalance set point range: 5% to 15% of nominal input voltage
  • Time delay range: 0.5 to 10 seconds
  • Output contact: DPDT, 5A at 240v AC
  • Reverse power relay module 
  • Nominal input voltage: 69v AC
  • Minimum input voltage: 120% of nominal input voltage
  • Nominal input current: 5A AC
  • Maximum input current: 200% of nominal input current
  • Reverse power set point range: 2% to 20%
  • Time delay range: 0 to 20 seconds
  • Output contact: DPDT, 5A at 240v AC
  • Electromechanical relay module
  • Nominal input voltage: 220v AC
  • Minimum input voltage: 10% of nominal input voltage
  • Maximum input voltage: 10% of nominal input voltage
  • Maximum current: 300mA
  • Auxiliary switching option: NO & NC
  • Output contact: TPST, 16A at 450V 
  • Motor power factor relay module
  • Nominal input voltage: 415v, 3 phase
  • Minimum input voltage: 90% of nominal input voltage
  • Maximum input voltage: 110% of nominal input voltage
  • Minimum input current: 0.5A AC
  • Maximum input current: 6A AC
  • Power factor set point range: 0 to 0.9
  • Start delay range: 0 to 20 seconds 
  • Output contact: SPDT, 10A at 250v AC
  • Work station: All module in a portable single station
  • Probes: 25pcs, Max load 15A

Required Document

  • Manufacturers Authorization Letter must submitted
  • ISO Certificate submitted
  • Catalog submitted
  • Warranty: 01 year warranty with service.

Enquiry Form