Switchgear & Protection Trainer

Order Code: 18193308.2.4

Category: General Lab Equipment III

Feature; Show skill in connecting cutout, MCB/MCCB in a circuit. Test the rating of circuit breaker (6A-10A) Demonstrate poly-phase system and phase sequence. Show skill in connecting Phase Fault Relay Show skill in phase missing test ...



SPECIFICATION

Feature;

  • Show skill in connecting cutout, MCB/MCCB in a circuit.
  • Test the rating of circuit breaker (6A-10A)
  • Demonstrate poly-phase system and phase sequence.
  • Show skill in connecting Phase Fault Relay
  • Show skill in phase missing test
  • Show skill in Overvoltage test
  • Show skill in Under voltage test
  • Show skill in phase sequence test
  • Perform star-delta conversion in a power system.
  • Study the different parts of an energy meter.
  • Study the different parts of a Busbar, Thermal over load relay, Magnetic contact, Timer etc.
  • Measure the energy of a three-phase circuit by three phase energy meters.
  • Perform the identification of the parts of a three-phase induction motor.
  • Start a 3-phase induction motor by star-delta starter using magnetic contactor switch.
  • Start a 3-phase induction motor by Auto star-delta starter using Timer & magnetic contactor
  • switch.
  • Categorize different types of fuses and measure the current 
  • carrying capacity of HRC fuse.


Specification:

  • Three Phase AC/DC Power Supply:
  • Rated Input Voltage: min.400 V AC (±5%) Three Phase 4-wire
  • Rated Output Voltage: min.400 V AC (±5%) Three Phase 4-wire
  • Rated Output Voltage:0— 400 V AC (±5%), Three Phase 4-wire
  • Rated Output Current: 5 AC (±5%)
  • Rated Output Voltage: min.120 V DC (*5%) ,5Amp
  • Rated Output Voltage:0• 220 V DC (±5%) ,5Amp
  • Short Circuit Protection Facility
  • 4mm safety jack Connection facility
  • Air Cooling system facility
  • Control Board:
  • Three Phase Energy Meter: min.1 EA
  • BAS Bar: min. 4EA
  • Circuit Breaker: min. 3EA (I °Amp)
  • Cartridge Fuse: min.3EA (l °Amp)
  • HRC Fuse: min. 3EA (15Amp)
  • Thermal Overload Relay: min.1 EA
  • Phase fault Relay: min.lEA
  • Digital Timer: min.2EA
  • Magnetic Contractor: min.3EA
  • Selector Switch: min.2 EA
  • Rated Input Voltage: min. 400 V AC (±5%) ,5OHz Three Phase 4-wire
  • 1 Training Manual
  • Weight: 100Kg (min.)
  • Power requirements: 220-240V AC, min.50Hz
  • Warranty: min. 0I(One) Year supported by performance security. Beyond 01 (One) year manufacturer warranty applicable. In that 
  • case supplier should provide warranty card/manufacturer document prior to expiration of performance security.