Switch-gear & Protection Trainer

Order Code: 23246902.3

Category: General Lab Equipment III

Feature; 1. Show skill in connecting cutout, MCB/MCCB in a circuit., 2. Test the rating of circuit breaker(6A, 10A), 3. Demonstrate poly-phase system and phase sequence., 4. Show skill in connecting Phase Fault Relay, 5. Show skill in ...



SPECIFICATION

Feature;

1. Show skill in connecting cutout, MCB/MCCB in a circuit.,

2. Test the rating of circuit breaker(6A, 10A),

3. Demonstrate poly-phase system and phase sequence.,

4. Show skill in connecting Phase Fault Relay,

5. Show skill in phase missing test,

6. Show skill in Overvoltage test,

7. Show skill in Under voltage test,

8. Show skill in phase sequence test

9. Perform star-delta conversion in a power system.,

10. Study the different parts of a energy meter.,

11. Study the different parts of a Busbar, Thermal over load relay, Magnetic contact, Timer etc.,

12. Measure the energy of a three phase circuit by three phase energy meter.,

13. Perform the identification of the parts of a three phase induction motor.

14. Start a 3-phase induction motor by star-delta starter using magnetic contactor switch.,

15. Start a 3-phase induction motor by Auto star-delta starter using Timer & magnetic contactor,switch.,

16. Categorize different types of fuses and measure the current carrying capacity of HRC fuse.

 

Specification:

Three Phase AC/DC Power Supply: Rated Input Voltage: 400 V AC (±5%) Three Phase 4-wire,Rated Output Voltage: 400 V AC (±5%) Three Phase 4-wire,Rated Output Voltage:0~ 400 V AC (±5%) ,Three Phase 4-wire,Rated Output Current: 5 AC (±5%) ,Rated Output Voltage: 120 V DC (±5%) ,5Amp,Rated Output Voltage:0~ 220 V DC (±5%) ,5Amp,Short Circuit Protection Facility 4mm safety jack Connection facility,Air Cooling system facility,Control Board:Three Phase Energy Meter: 1 EA,BAS Bar :4EA Circuit Breaker :3EA (10Amp) Cartridge Fuse:3EA (10Amp) HRC Fuse: 3EA (15Amp)Thermal Overload Relay: 1 EA Phase fault Relay: 1EA Digital Timer: 2EA Magnetic Contractor: 3EA Selector Switch:2 EA Rated Input Voltage: 400 V AC (±5%) ,50Hz Three Phase 4-wire · 1 Training Manual,· 4mm safety banana socket,· Size (L x W x H)= (60?x36?x12?),· Weight: 100Kg (Approx),· Power requirements: 220~240V AC, 50Hz · Built-in short circuit protection system. Required Documentations: - Installation, Testing, Commissioning, and Training should be performed by qualified and experienced engineers including required raw materials at bidder's own cost. - Warranty: 01(One) Year supported by performance security - Manufacturers Authorization Letter must be submitted.,- ISO or CE certificate must be submitted.- Catalog / Brochure should be submitted.''

Enquiry Form