Technical Specifications 1)   SCADA components A)    PCs:  4th  generation  IntelÒ  CoreÔ,2.9GHz,2-  Core,OS: Windows 8.1, Memory: 8GB, HDD: 500GB, Smart space-savin...



SPECIFICATION

Technical Specifications
1)   SCADA components
A)    PCs:  4th  generation  IntelÒ  CoreÔ,2.9GHz,2-  Core,OS: Windows 8.1, Memory: 8GB, HDD: 500GB, Smart space-saving All-in-One design with a full-metal V-stand-4Nos.
  1. Supervisor`s desk: Touch panel PC with 8 port Ethernet switch-1nos
  2. HMIs as local stations: Touch panel PC placed near each Rtu unit with convenient swivel angle-3nos
  3. Uninterruptible Power Supply: Provided (500VA/30 min. backup) one each for supervisory PC & 3 HMl station to prevent corruption due to brownouts.- 4nos.
 
B)    Software:
  1. Multi drop SCADA software with 4 numbers of USB based runtime hard keys, of which 2 are for unlimited tags & two are of 300 tags.
  2. SCADA screens supported: Generator control panel screen, synchronization screen Generator different protection relay screen, load screen selection screen, Double bus bar screen, transmission line screen, symmetrical & unsymmetrical fault screen, Distance protection screen, Distribution Transmission different protection screen, power measurement screen, Alarm and event management screen etc.
 
C)    RTUs: Table top aluminum profile rack of 3X1 panels consisting - 3nos.
  1. Each PLC (48l/O) has 24 inputs (24V) & 24 output (Relay additionally 2al & 3AO. Each PLC has RS485 modbus interface, Ethernet interface, 8 relay output card (max 3nos) with contacts at 230vac with terminal strip for easy servicing.
  2. Converter cum distribution panel (CDP) supporting 37 pin & 9 pin D connectors for control & collecting trip signal from protection relays if any. 
  3. RTU Unit with HMI
  4. phase 4P/16A@415vac contactors for power topology control, fault insertions & CB control-20nos (max).
  5.  Goggle coloured transparent Perspex glass cover to protect students from HV compnents / contactors.
D)    IEDs:
  1.  Multifunction meter EMT34: Consist of (96 X 96 mm) Digital meters for 3 phase, VARs, energy etc. with RS485 modbus communication interface facility--15nos.
  2. Phase angle measurements-2nos
  3. Protection Relays: Numeric relays with modbus RS485 interface.-4nos
  • Generator protection differential relay provides differential, over/under voltage frequency, reverse power, earth fault , directional/non directional etc.
  • Distance protection relay provides distance zone, directional/non directional over current, earth fault, Under/Over voltage protections, auto reclose function etc.
  • Transformer differential protection relay provides differential protection & over current protection for distribution transformer.
  • Automatic  synchronization  relay  provide automatic synchronization between generator & Grid supply.