PERFORMANCE SPECIFICATION FOR STATIC CONVVERTER SCOPE :- Our specification covers design, manufacturing, inspection, testing, supply of the DRIVE. INPUT SYSTEM :- Normal Voltage : 415V /- 10% No of phases : Three phase, fou...



SPECIFICATION

PERFORMANCE SPECIFICATION FOR STATIC CONVVERTER
  1. SCOPE :- Our specification covers design, manufacturing, inspection, testing, supply of the DRIVE.
  2. INPUT SYSTEM :-
    • Normal Voltage : 415V /- 10%
    • No of phases : Three phase, four wire
    • Frequency : 50Hz /- 2%
    • Fault level : 20KA RMS at 415 V.
    • Neutral earth : Solidly earthed.
  3. TECHNICAL PARTICULARS :-
    • Output Voltage.
      • Armature : 440V DC Max.
      • Field : 220V DC
      • DC Motor Blower : 415V /-10%, 50Hz /-2%, 3Ph.
    • Output Current.
      • Armature :
      • Field :
    • Speed Control.
    • Accuracy of speed control. /-2% under Arm. Voltage feedback.
    • Soft start.Acceleration and deceleration control from 5sec to 30sec adjustable.
    • Type of control : Tacho/Arm. Voltage feedback.
    • Direction of rotation.:
    • Braking.
    • Type of cooling : Forced air cooling
  4. CONVERTER MODULES. It consists of the following modules.
  • Input module
  • Thyristor module
  • Regulation module
  • Output module
  • Excitation module
  • Indicating and operating module
  • Protection module
  • Input moduleThe incoming 415V 3PH four wire supply will be brought into this module. It consists of
    • Tripple pole and neutral incoming AC heavy duty isolator switch.
    • Three nos. HRC fuse link for mains.
    • Main contactor
    • Line surge suppressor consisting of capacitors, resistors & MOVs.
  • ThyristormoduleIt will consist of three phase, full wave, fully controlled thyristor bridge assembly comprising of
    • Six nos. derated thyristors each mounted on Aluminium heat sinks
    • RC Snubber circuit for power semi-conductors.
    • MOVs to protect thyristors against spikes.
    • Pulse transformers to isolate the control circuit from power circuit.
    • Forced cooling arrangement.