Feature All outputs continuously variable. Built – in crystal time base multi range DIGITAL TIMER. True RMS digital metering of outputs. Compact rugged design – Fully tropicalised. Auto-switch off in all modes of operation. ...



SPECIFICATION

Feature

  • All outputs continuously variable.
  • Built – in crystal time base multi range DIGITAL TIMER.
  • True RMS digital metering of outputs.
  • Compact rugged design – Fully tropicalised.
  • Auto-switch off in all modes of operation.
  • All current outputs fully isolated and distortion free.
  • Suitable for testing thermal devices
  • All controls and metering centralized.

 

Technical Specification

Rating

5 Minutes ON / 15 Minutes OFF. Continuous rating does not exceed 50% of the rated output.

Metering

1) LED digital Ammeter, CT operated for current outputs. 2) LED digital Voltmeter for voltage output.

Accuracy

± 1% ± 3 counts.

Digital Timer

4 digit, solid state crystal base timer system. Multi range from .0001 to 9999 seconds.

Accuracy

± 0.5 % ± 2 counts

Timer Control Circuits

The timer automatically starts when the output is initiated and automatically stops when the device under test operates.

Start Signal

Internal.

Stop Signal

Via-either normally open or normally closed external contacts.

Auto-Cut-Off

Cuts off output on operation of device under test.

Operation

Circuit breaker in input, mains on indicator, contractor controlled push buttons for current output on or off, contact mode selector and reset switch. ‘SET/TEST’ switch to set up test current level.

Construction

Two piece unit. Sheet steel cabinets powder coated and with fold away lifting handles.

Optional Accessories

  1. Low inductance lead set.
  2. Precision grade (0.5%) Analogue meter with Current transformer.

 