PLC Operated Temperature Flow Level Pressure Vibration & Weight Measurement Trainer

Order Code: 21225225.5

Category: General Lab Equipment I

Metal holder with Plexiglas vertical panel 3 tanks: lower one in ABS, about 12 lt. capacity; upper one (Plexiglas column), 5 lt; side one in steel, 1 lt. Recirculation pump, 6 lt/min 12 V - 7A Manual valves 48 V 200 W water heater Safe...



SPECIFICATION

  • Metal holder with Plexiglas vertical panel
  • 3 tanks: lower one in ABS, about 12 lt. capacity; upper one
  • (Plexiglas column), 5 lt; side one in steel, 1 lt.
  • Recirculation pump, 6 lt/min 12 V - 7A
  • Manual valves
  • 48 V 200 W water heater
  • Safety thermostat
  • 1 mercury glass thermometer (-20 °C a + 110 °C)
  • 2 Proportional valves, bronze body 0-10 V
  • 2 manometers 0-4 bar
  • External unit connection with 4 mm diameter terminals and
  • DIN connectors
  • ON/OFF solenoid valve
  • Flow sensors: 1 turbine-type, 1 magnetic-type for ON/OFF
  • control
  • Level sensors: 1 ON/OFF-type, 1 piezometric-type
  • Temperature sensors: 1 Pt100-type, 1 thermocouple J-type, 1
  • PTC-type, 1 NTC-type.
  • Pressure sensor: 1 piezometric-type, 1 ON/OFF-typeTabletop metal box with press-formed aluminium section
  • structure
  • Side handles , not protruding, for easy transport in the
  • laboratory
  • Front panel, in insulating material, with silk screen
  • representation of the diagrams and inner components of the
  • equipment
  • 24 Vdc/3 A power supply for control of the digital inputs and
  • outputs. With electronic protection against short-circuits and
  • overloads.
  • 24 Vac/3 A power supply relay outputs control with fuse
  • protection against overloads
  • 1 3 and 1/2-digit digital voltmeter for measurement of the
  • voltage present across the inputs or the analog output 0.1
  • Vdc resolution.
  • 1 Rotating switch for voltmeter input selection
  • 4 analog inputs V/I: ±10 Vdc, ±20 mA
  • 1 input for Pt 100 temperature probe
  • 2 analog outputs V/I: ±10 Vdc, ±20 mA
  • 4 Rotating potentiometers for setting up voltage analog
  • references in the range 0..10 Vdc
  • Inner voltage reference obtained via 24 Vdc inner stabilizer
  • 24 Digital standard inputs of which 12 special for technologic
  • functions (counting, frequency measurement max 60 kHz.
  • Digital input simulator with permanent and pulse state
  • switchesArchitecture of a PLC, synchronous cycles, asynchronous
  • cycles and cycles with priority
  • Run-time, cycle time and response time
  • Boolean algebra (NO and NC contact, logical functions)
  • Programming in AWL, KOP, FUP, GRAPH, SCL languages
  • Functions of combinational and sequential logic
  • Addressing operationsTimers & counters
  • PID control
  • Creation of HMI pages
  • The software block of PLC simulation enables to test the
  • program (OFFLINE) before it is transferred onto the actual
  • device. The software is also provided with the following
  • examples of exercises carried out:
  • Logic gates
  • Function modules
  • Starting an asynchonous motor
  • Reversal of rotation in an asynchronous motor
  • Star/delta starting of an asynchronous motor
  • Star/delta reversal of rotation
  • Linear position control
  • Starting a Dahlander motor
  • Motor with two separate coils
  • Starting an asynchronous wound-rotor motor
  • Installation,Commissioning,Operation,
  • Testing & Training. must be provided and brand must be mention by the bidder
     

Enquiry Form