Order Code: 19204136.3.3
Category: General Lab Equipment III
Item Description Readability (%) Moisture Range Repeatability with 2g sample (%) Repeatability with 10g sample (%) ...
Item |
Description |
Readability (%) |
Moisture Range |
Repeatability with 2g sample (%) |
Repeatability with 10g sample (%) |
Able to display |
%MC; %DC; %AM; %AD; g; g/kg MC; g/kg DC |
|
Plastic, PBT, Crastin SO653-GB20 Plastic, PEEK-HT G22 (UL94-V0) Glass ceramics Quartz glass Stainless steel, X2CrNiMo17-2 (1.4404) Plastic, PEEK-HT G22 (UL94-V0) Stainless steel, X2CrNiMo17-2 (1.4404)
EN ZL-ZnAl4Cu1 (EN Zl-0410) PA12 GB3
|
|
|||||
Switch off criterion |
Timed, and automatic |
|
|||||
|
|
|
|||||
Results handling |
Control Chart Pass/fail indication Drying Curves |
|
|||||
Drying programs |
3 (Standard, Rapid & Gentle) |
|
|||||
Display |
7” Touch Screen, also supports one touch method short-cuts via touch screen for operation |
|
|||||
Drying Curve |
Real time display of drying curve with sample management ID |
|
|||||
Connectivity |
Ethernet, RS-232C, USB device, USB Host (2), WiFi |
|
|||||
Printing |
A4/Letter, strip print outs, PDF documents |
|
|||||
Power supply 110 V AC Version 230 V AC Version Voltage fluctuations Power load Power line fuse |
100 V–120 V, 50/60 Hz, 4 A 220 V–240 V, 50/60 Hz, 2 A -15%+10% max. 450 W during drying process 5 x 20 mm, T6.3H 250 V |
|
|||||
Hardware Drying unit Sample chamber opening/closing Leveling Sample pan Thermal overload protection
Dimensions (w x h x d) Weight, ready to measure
Terminal Display Reading angle Dimensions (w x h x d) Weight |
Manual 2 leveling screws Ø 90 mm Bimetallic-element switch in heating module
199 x 139 x 428 mm 6.8 kg
WVGA color display, resistive touch-sensitive Adjustable, 2 folding feet 200 x 63.5/79.5 x 134.5 mm 1.2 kg |
|
|||||
Sample facility |
CD style automatic sample drawer |
|
|||||
Operational manual (in English and/or French) |
To be supplied
|
|
|||||
Test & Adjust |
SmartCal; Temperature (100/160);Weight |
|
|||||
Calibration certificate from accredited lab |
To be provided |
|
|||||
Protection and standards Overvoltage category Degree of pollution Range of application |
II 2 For use in dry interior rooms |
|
|||||
Environmental conditions Height above sea level
Ambient temperature range
Relative air humidity
Warm-up time
|
up to 4000 m
Operation: +10 °C to 30 °C (operability guaranteed 5 °C to 40 °C)
Max. 80% up to 31 °C, linearly decreasing to 50 % at 40 °C 20% - 80% and non-condensing conditions
At least 60 minutes after connecting the instrument to the power supply; when switched on from standby, the instrument is ready for operation immediately
|
|
|||||
Accessories and spares
3 days theoretical and practical training on High Accuracy Moisture Meter at National Metrology Laboratories-RSB and training certificates to be issued for 3 staff after completion of training. Note: No online training shall be acceptable. |
|