IoT Sensor Circuits Trainer

Order Code: 23246630.6

Category: General Lab Equipment II

Module One: Chapter 1 Photo Sensor Circuits Experiment 1 : CdS Sensor Circuit Operating Wave length : 500 nm - 580 nm Experiment 2 : Photo Diode circuit Operating Wave length : 76nm - 1000 nm Experiment 3 : Phototransistor Circuit O...



SPECIFICATION

Module One:

  1. Chapter 1 Photo Sensor Circuits
  2. Experiment 1 : CdS Sensor Circuit
  3. Operating Wave length : 500 nm - 580 nm
  4. Experiment 2 : Photo Diode circuit
  5. Operating Wave length : 76nm - 1000 nm
  6. Experiment 3 : Phototransistor Circuit
  7. Operating Wave length : 430nm - 670 nm
  8. Experiment 4 : Photo Interrupter Circuit
  9. Operating Wave length : 940 nm

Module Two:

 

  1. Chapter 2 Switch Sensor circuit
  2. Experiment 1 : Tilt Switch Circuit
  3. Conduction Angel : 55-125 deg.
  4. SW Normal State : ON
  5. Operating State : LED Indicator
  6. Experiment 2 : Micro Switch Circuit
  7. SW Normal State : OFF
  8. Operating State : LED Indicator
  9. Experiment 3 : Touch Switch Circuit
  10. SW Normal State : OFF
  11. Operating State : LED Indicator
  12. Experiment 4 : Reed Switch Circuit
  13. SW Normal State : OFF
  14. Operating State : LED Indicator
  15. Experiment 5 : Vibration Switch Circuit
  16. SW Normal State : ON
  17. Operating State : LED Indicator

Module Three:

  1. Chapter 3 Temperature Sensor circuit
  2. Experiment 1: MCP9701 Temperature Sensor Circuit
  3. Measurement Range: - 40?C to +125?C
  4. Accuracy (max.): ± 4?C @ (0?C to +70?C)
  5. Experiment 2: LM335 Temperature Sensor Circuit
  6. Measurement Range: - 40?C to +100?C
  7. Accuracy (max.): ± 2?C @ 25?C
  8. Experiment 3: TC620 Temperature Sensor Circuit
  9. Experiment4: TC74 Temperature Sensor Circuit
  10. Measurement Range: - 40?C to +125?C
  11. Accuracy (max.): ± 3?C @ (0?C to +125?C)

Module Four:

  • Chapter 4 Humidity Sensor Circuits
  • Experiment 1: H25K5A Humidity Sensor Circuit
  • Measurement Range: 20% - 90% RH
  • Accuracy (max.): ±5% RH@25°C
  • Experiment 2: Sl7007 Humidity Sensor Circuit
  • Measurement Range: 0 - 100% RH
  • Accuracy (max.): ±5% RH@ (0 - 80% RH)
  • Experiment 3: RH818 Humidity Sensor Circuit
  • Measurement Range: 0 - 100% RH
  • Accuracy (max.): ±1% RH@ (10% - 90% RH)
  • Experiment 4: DHT11 Humidity Sensor Circuit
  • Measurement Range: 20% - 90% RH
  • Accuracy (max.): ±5% RH@ 25°C

Module Five:

  • Chapter 5 Infrared Sensor Circuits
  • Experiment 1: RE200B Passive Infrared Sensor Circuit
  • Frequency Response: 0.3 Hz - 3 Hz/±10 dB
  • Field of View: 21 ° - 159° (X axis), 27.5° - 152.5° (Y axis)
  • Experiment 2: OTP-628 Thermopile Infrared Sensor Circuit
  • Thermopile Voltage: 2.6±0.8 mV
  • Field of View: 45 ° - 135 ° (X axis), 45° - 135° (Y axis)
  • Experiment 3: TS-S2NMB Thermopile Infrared Sensor Circuit
  • Thermopile Voltage: 2.43±0.6 mV
  • Field of View: 45 ° - 135° (X axis), 45° - 135° (Y axis)

Module Six:

  • Chapter 6 Gas Sensor Circuits
  • Experiment 1: Smoke Sensor Circuit
  • Sensing Body Resistance: 1 k? - 10 k? (1000 ppm lsobutane)
  • Operating Humidity: <95% RH
  • Operating Oxygen Concentration (min.): >2%
  • Experiment 2: Nature Gas Sensor Circuit
  • Sensing Body Resistance: 2 k? - 20 k? (5000 ppm Methane)
  • Operating Humidity: <95% RH
  • Operating Oxygen Concentration (min.): > 2%
  • Experiment 3: Alcohol Sensor Circuit
  • Sensing Body Resistance: 100.k - 500 k (100 ppm Alcohol)
  • Operating Humidity: <95% RH
  • Operating Oxygen Concentration (min.): > 2%
  • Experiment 4: Carbon Monoxide Sensor Circuit
  • Sensing Body Resistance: 2 k? - 20 k? (100 ppm Carbon Monoxide)
  • Operating Humidity: <95% RH
  • Operating Oxygen Concentration (min.): > 2%

Module Seven:

  • Chapter 7 Ultrasonic Sensor Circuits
  • Experiment 1: Sound Generator
  • Frequency: 850±100 Hz Arnd 1700±150 Hz
  • Experiment 2: Ultrasonic Transmitter
  • Operating Frequency: 40 kHz
  • Operating Temperature: -20°C ~ +70°C
  • Operating Humidity: <90% RH@40°C
  • Experiment 3: Ultrasonic Receiver
  • Operating Frequency: 40 KHz
  • Operating Temperature: -20°C ~ +70°C
  • Operating Humidity: <90% RH@40°C

 

Module Eight:

  • Chapter 8 Color Sensor Circuits
  • Experiment 1: Red Sensor Circuit
  • Operating Wave length: 590 nm ~ 720 nm (p: 660 nm)
  • Experiment 2: Green Sensor Circuit
  • Operating Wave length: 480 nm ~ 660 nm (p: 540 nm)
  • Experiment 3: Blue Sensor Circuit
  • perating Wave length: 400 nm ~ 540 nm (p: 460 nm)
  • Function Generator and DC Power Supply
  • Waveforms: Sine, Triangle, Square, TTL Pulse
  • Amplitude: >10 Vpp
  • Impedance: 50Ω ±10%
  • Duty Control: 30% ~ 60%
  • Display: 6-Digit LED Display

Enquiry Form