Instrument for Measurement of Liquid Thermal Properties

Order Code: 21224924.3.2

Category: General Lab Equipment II

Scope: Supports the measurement system for the determination of the thermal conductivity of liquids and pastes according to ASTM D7896-19 Standard test method. (Standard Test Method for Thermal Conductivity, Thermal Diffusivity and Volumetric Heat C...



SPECIFICATION

Scope:
Supports the measurement system for the determination of the thermal conductivity of liquids and pastes according to ASTM D7896-19 Standard test method. (Standard Test Method for Thermal Conductivity, Thermal Diffusivity and Volumetric Heat Capacity of Engine Coolants and Related Fluids by Transient Hot Wire Liquid Thermal Conductivity Method) 

  • Capable of measuring the thermal conductivity of liquids 
  • Capable of measuring the temperature of liquids 
  • Capable of measuring thermal diffusivity of the liquids

Technical specifications 

  • Measuring Materials: Liquids, Gels and Pastes 
  • Thermal Conductivity Range: 0.01 to 2 W/mK (Watts per meter-Kelvin)
  • Temperature Range: -50 OC to 300 OC (or above) 
  • Accuracy: ±2 % (Or better accuracy) 
  • Repeatability Limit: 1 % (Or better repeatability
  • Temperature sensor: ± 0.1 OC Accuracy in the temperature range of -50 OC to 300 OC (or above)
  • Sample Volume: 40 ml (Or smaller volume)
  • Measuring time: 30 seconds (Or lesser time) 
  • Display: LC-Display 
  • Device size: Benchtop device

Components :

  • Sensor with sample cup: o Material: Standardized metal or noble metal as the thermal insulator coating 
  • Temperature sensor: ± 0.1 OC Accuracy in the temperature range of -50 OC to 300 OC (or above) 
  • Temperature Range: -50 to 300OC (or above) o Maximum Pressure: 30 bar (or above) 
  • Software: Windows OS compatible software 

Block Thermostat: 

  • Supports for automatic temperature control of the sample 
  • Compatible with the thermal conductivity meter for the fully automatic determination of the thermal conductivity of liquid

Temperature Range: 

  • From Room Temperature to 300 OC (or above) 
  • Temperature Stability: ± 0.3oC (Or better stability)
  •  Power cable for thermal conductivity meter 
  • Power cable for block thermostat 
  • Data cable for PC to the thermal conductivity meter connection 
  • Data cable for thermal conductivity meter to block thermostat connection 
  • Any other cable for the perfect operation of the instruments

Power Supply:

  • AC Power supply with 230/240V, 50 Hz (For both thermal conductivity measuring instrument and the block thermostat
     