Generation Trainer with Protection Relays

Order Code: TPO-TRT-GEN

Category: Electrical Machine Lab

Salient Features Facilitates generator protection using numerical generator protection relay. VFD drive used to control brushless prime mover's speed in manual mode. Multi function meters read the input voltage & frequency of genera...



SPECIFICATION

Salient Features

  • Facilitates generator protection using numerical generator protection relay.
  • VFD drive used to control brushless prime mover's speed in manual mode.
  • Multi function meters read the input voltage & frequency of generator output along with power analyser data. (optional)
  • The Generator/ alternator coupled with prime mover have brought out six terminals from three phase 3 windings (RYBs). The every alternate terminal of RYB is shorted and connected together to form Star connection (Neutral) at the output of generator.
  • The relay panel carries shrouded sockets to connect Generator Protection relay mounted below. The CT panel and PT panel provide necessary interface between real world & relay.
  • Emergency stop mushroom switch is provided with security key lock on the profile rack.
  • Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords and shrouded socket arrangements for high voltage circuits
  • Each panel has ABS molded plastic sturdy enclosure, and colorful screwless overlays showing circuits diagrams & its connection tag numbers for easy understanding and connection
  • Set of Instructor Guide & Student Workbook.

 

Technical Specifications
Trainer can work in standalone mode with simulated grid sources consists of following panels.:

  • Input 3 phase DOL Starter panel (EMT1x 1 No.]
    • 4 pole MCB of 415 V/20A.
    • DOL 16A Contactor with 230V/50Hz/11VA COIL
    • Bimetallic thermal O/L relay with range 9A - 15A
    • RYB inputs indicators.
    • 9 pin D (M) connector
    • Manual start / stop with local trip contact
    • Power ON LED indicator
    • Green SBS5 socket is provided for extend earth.
    • DC Volt meter & DC ammeter Panel (EMT6Bx 1 No.)
    • DC voltmeter 0-300VDC
    • DC ammeter 0-5A
    • 4A circuit breaker.
  • Instrumentation power supply cum multichannel DPM panel (EMT8x 1 No.)
    • DC Multi Output power supply.
    • Supplies DC power to neighbouring signal conditioning circuit. panels like EMT9, CIP1, CIP2, MIT12, CE7 etc. through 20 pin FRC cable.
    • Provides 1 Ph. AC supply through 3 MCB's, 4A each to power up other panels in the rack.
    • Optionally Multichannel 4 position DPM for Speed, Torque etc.
    • Green SBS5 socket is provided for extend earth.
  • Variable AC and DC supply panel (EMT23 x 1 No.)
    • Input 0-230VAC, 50Hz
    • Variable O/P: AC 0-270V/3A
    • Variable O/P: DC 0-250V/3A.
  • IGBT Controlled VVVF Drive panel (EMT33A x 1 No.)
    • Input voltage: 3 phase, 415VAC. 50Hz
    • Output voltage: 3 phase 415VAC
    • Range (Frequency Control) : 0.1 Hz to 100 (400)Hz
    • Control Mode :Sine Wave PWM
    • Capacity : 10 HP
    • With Reverse And Forward Direction
    • 3 phase EMI Inductor.
    • Mod bus RS485 interface. (optional)
  • 3 Phase Bidirectional Power cum Energy meter panel (EMT34 x 4 Nos.)
    • Bidirectional Multifunction
    • 3 phase 3/4 wire, 415VAC, CT Input 5A
    • LCD/LED display, Aux. supply 230V, 45-65Hz,5W
    • Measure V. I., Hz, Pf, KVA, KW, KWH
    • Green SBS5 socket is provided for extend earth.
  • SCR Actuator (variable DC) cum sensor signal conditioning panel (EMT9) X 1 No.
    • Full bridge SCR based 0V-195V / 3 Amp cosine firing with linear characteristics.
    • Supports signal conditioning circuit for speed, torque in kg to give output 0-2.5Vdc (FS).
    • External control signal (0 - 2.5VDC) to set O/P volt (0-100VDC) to control excitation.
  • Generator Protection Relay panel (EMT47B) x 1No.
    • Protections: Differential, Over current, Under/Over voltage, Under/Over frequency, Reverse power, Earth fault.
  • CT panel (EMT48) x 1 No.
    • Consist of 5/5 Amp. CT 6 Nos.
    • Primary side of CTs are brought on 3 x 2 x 2 SBS-5 sockets.
    • Secondary side of CTs are Star connected in group of 3 & brought out on 4 x 2 SBS-5 sockets
  • 415/110VAC, 50VA PT panel (EMT54) X 1 No.
    • Consisting of potential transformer,
    • Input 415VAC, star connected, Output 110VAC, star connected, 50VA.

 

Table top panels:

  • Generator transformer Panel (EMT54B) X 1 No.
    • 3 phase power transformer with connection group Yy11,
    • Input 415VAC, Output 415VAC, 5KVA,
    • Secondary winding with tapping at +/-2.5% and +/-5%.
  • 3 phase Squirrel cage Induction Motor Panel (EMT65) X 1 No.
    • Voltage: 3 phase Delta connected, 415 VAC, 50Hz,
    • Capacity/RPM /Terminals: 3HP/4 Pole m/c / 1500RPM/ 6 terminals.
    • Rotor Construction: Diecast Squirrel cage rotor.
    • Stator construction: 3x2 terminals,
    • Frame/ Mounting Shaft dia : 112 Frame, Chasis mounted 38mm dia. with easily swappable gear coupling.
  • 3 phase Salient Pole Alternator Panel (EMT66) x 1 No.
    • Voltage : 3 phase, star connected, 415VAC, 50Hz
    • Capacity/RPM /Terminals : 3KVA/4 Pole m/c / 1500RPM
    • Rotor Construction: Rotor excited 180Vdc/2.65A, two terminals brought out on 2 slip rings mounted on shaft.
    • Stator construction: Six terminals brought out for star connection.
    • Frame/ Mounting Shaft dia : 132 Frame, Chasis mounted 28mm dia. With easily swappable gear coupling

 

.List of Experiments:

  • Study of V curve & inverted V curve.
  • Study of Generator performance chart.
  • Study of generator protection for differential, over current, over/under voltage, over/under frequency, reverse power and earth faults using generator protection relay.

 

Mechanical Dimensions (mm)& Weight of Trainer:

  • 1165(L)x300(W)x990(H)
  • Net. Wt.: 65 Kg.
  • Gross Wt.: 73 Kg.
  • 3 Ph. Sq. Cg. motor Net Wt.: 40 kg.
  • Gross Wt.: 52 kg.
  • 3 Ph. Salient alternator Net Wt.: 35 kg. Gross Wt.: 47 Kg.

Enquiry Form