Order Code: 24258098.77
Category: General Lab Equipment V
Free and forced convection Calculation of convective heat transfer at different geometries: flat plate, cylinder, tube bundle Features free and forced convection using the example of various heating elements network capability: network acce...
Free and forced convection
Calculation of convective heat transfer at different geometries: flat plate, cylinder, tube bundle
Features
Specification
Technical data
Air duct
• flow cross-section: 120x120mm
• height: approx. 0,6m
Heating elements, temperature limitation: 90°C
• tube bundle
• number of tubes: 23
• one tube in variable position is heated
• heating power: 20W
• heat transfer area: 31,41cm2
• cylinder with an even temperature at the surface
• heating power: 20W
• heat transfer area: 111cm2
• plate
• heating power: 40W
• heat transfer area: 2x 100cm2
• cylinder with heating foil to investigate the local heat transfer
• heating power: 40W
• heat transfer area: 111cm2
Axial fan
• max. flow rate: 500m3/h
• max. pressure difference: approx. 950Pa
• power consumption: 90W
Measuring ranges
• air velocity: 0...10m/s
• temperature: 4x 0...325°C
• heating power: 0...50W
230V, 50Hz, 1 phase