Fire Alarm Trainer

Order Code: 46631

Category: Electrical Machine Lab

Technical Specifications  A] Aluminum profile modular flat demo panel rack system (table top) carrying carious components housed in plastic enclosures (panels) to minimize shock possibility, in top three rows. The bottom row holds control panel...



SPECIFICATION

Technical Specifications
 A] Aluminum profile modular flat demo panel rack system (table top) carrying carious components housed in plastic enclosures (panels) to minimize shock possibility, in top three rows. The bottom row holds control panel with batteries.
  1. 1 phase AC Input Supply panel (EMT16A)
    • 1ph. dual MCBs of 2A for short circuit protection
  2. Smoke detector panel (FAT1)
    • Photoelectric smoke sensor
    • Operating voltage - 12VDC
    • Standby current - 20uA
    • Alarm current - 35mA@12VDC
    • Alarm output - Remote LED
    • Temperature - 0% ~ 95%RH
  3. Heat detector panel (FAT2)
    • Operating voltage: 12VDC
    • Static current :<55uA
    • Alarm current : <25mA@12VDC
    • Alarm output : Remote LED ON,
    • Temperature tripe point : 135°F (57°C)
    • Operating temperature :- 10°C~ 50°C, <95%RH
    • Detecting range :50 square meter with the installation height of 6m; 12m
  4. Manual call point(MCP) panel (FAT4)
    • Operating voltage: 12VDC
    • Resettable type: MCP
    • Active/de active LED indication
    • Push to activate & deactivate by plastic key
  5. Siren with flasher panel (FAT5)
    • Operating voltage: 12VDC@500mA
    • Power: 6W
    • Sound level: 105dB
    • Flashing rate: 150 per minute
  6. Gas (LPG) Leak detector panel (FAT3)
    • Operating voltage: 12VDC
    • Relay output contacts with max: 24V@1A
    • Inbuilt alarm indication buzzer
    • Inbuilt heat detector (trip point 60°C)
  7. Control panel (FAT6)
    • 2-Zone conventional control panel
    • Supply voltage: 230VAC /-10%/50Hz/max X 2W
    • 12VDC (6V,4.5A X2nos) rechargeable battery backup
    • Zone indication: Fire detection, sensor open, sensor short, sensor bypass & zone test indication
    • Status indication - system ON, fire indication, reset key hit, silence key hit, zone fault & siren ON
    • Fault indication : AC fail, Hooter fail, Battery low
    • 5 keys keypad
    • Keypad enable /desable by key lock
    • Relay output for siren with max: 24VDC@5A
    • Operating temperature: 0 to 50° C, <95% RH
    • Auxiliary output: 12VDC/500mA