Engineering Lab

Order Code: 21225024.1

Category: General Lab Equipment I

Analog Input, Number of channels-8 differential and 16 single ended 16 bit ADC resolution DC input coupling Input range: -10v to +10v Sample Rate maximum- 1 to 1.25 MS/s & no minimum  50 ppm of sample rate timing accuracy US...



SPECIFICATION

  • Analog Input,
  • Number of channels-8 differential and 16 single ended
  • 16 bit ADC resolution
  • DC input coupling
  • Input range: -10v to +10v
  • Sample Rate maximum- 1 to 1.25 MS/s & no minimum 
  • 50 ppm of sample rate timing accuracy
  • USB signal stream,programmed I/O data transfers. Maximum working voltage for analog inputs ±11V 90 dB CMRR (DC to 60 Hz)
  • Less than 1% Accuracy
  • Analog edge triggering,analog edge triggering with hysteresis, and analog window triggering modes. Overvoltage Protection (Al±,AISENSE) ±25 V dev.ON
  • Scanlist memory: 4095 entries minimum 
  • 1 analog trigger
  • Functions, Start Trigger, ReferenceTrigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase Number of counters/timers-2
  • 32 bit counter resolution 
  • 1 Mhz frequency
  • 2 No of waveform generator Output range ±10 V,±5V
  • DC output coupling
  • DMM functions- DC voltage, AC voltage, DC current, AC current, resistance and diode 
  • DMM Resolution - 5.5 digits
  • DC Voltage measurement range- 100mV to 60V 
  • AC Voltage measurement range-200 mV-20 Vrms 
  • DC and AC current range-0 to 2A max
  • 2 channel Oscilloscope and simultaneous sampling mode 
  • AC,DC,GND input coupling
  • Power source - 15v to +15v dc
  • USB 2.0 Hi-Speed bus interface communicationAnalog Input,
  • Number of channels-8 differential and 16 single ended
  • 16 bit ADC resolution
  • DC input coupling
  • Input range: -10v to +10v
  • Sample Rate maximum- 1 to 1.25 MS/s & no minimum 
  • 50 ppm of sample rate timing accuracy
  • USB signal stream,programmed I/O data transfers. Maximum working voltage for analog inputs ±11V 90 dB CMRR (DC to 60 Hz)
  • Less than 1% Accuracy
  • Analog edge triggering,analog edge triggering with hysteresis, and analog window triggering modes. Overvoltage Protection (Al±,AISENSE) ±25 V dev.ON
  • Scanlist memory: 4095 entries minimum 
  • 1 analog trigger
  • Functions, Start Trigger, ReferenceTrigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase Number of counters/timers-2
  • 32 bit counter resolution 
  • 1 Mhz frequency
  • 2 No of waveform generator Output range ±10 V,±5V
  • DC output coupling
  • DMM functions- DC voltage, AC voltage, DC current, AC current, resistance and diode 
  • DMM Resolution - 5.5 digits
  • DC Voltage measurement range- 100mV to 60V 
  • AC Voltage measurement range-200 mV-20 Vrms 
  • DC and AC current range-0 to 2A max
  • 2 channel Oscilloscope and simultaneous sampling mode 
  • AC,DC,GND input coupling
  • Power source - 15v to +15v dc
  • USB 2.0 Hi-Speed bus interface communication
     

Enquiry Form