ELECTRO-HYDRAULIC TRAINING SET-ADVANCED LEVEL

Order Code: 22235598.8

Category: General Lab Equipment II

Advanced Electro- Hydraulic  Training Set - The set consists of the following items: Relay, 3-fold-2 unit Power: 24 VDC Contact: 4 Contact load: max. 5 A Allowed load: max 90 W Response time: 10 ms Block time: 8 ms Digital ti...



SPECIFICATION

Advanced Electro- Hydraulic  Training Set - The set consists of the following items:

  1. Relay, 3-fold-2 unit
  2. Power: 24 VDC
  3. Contact: 4
  4. Contact load: max. 5 A
  5. Allowed load: max 90 W
  6. Response time: 10 ms
  7. Block time: 8 ms
  8. Digital time relay-1 unit
  9. Power : 24 VDC
  10. Contact : 2a,2b
  11. Contact load: Max. 5 A
  12. Allowed load : Max 100 W
  13. Delay time : 1 – 10 s
  14. Digital counter-1 unit
  15. Power : 24 VDC
  16. Contact : 1 C – contact
  17. Contact load: Max. 5 A
  18. Power consumption : 2.4 W
  19. Counter pulse : 20 ms
  20. Display : 4 digit
  21.   
  22. Push button switch set-1 unit
  23. Power: 24 VDC
  24. 2 momentarily, 1 locking
  25. Contact: 2 open, 2 closed
  26. Contact allowed load: Max. 1 A
  27. Power consumption: 0.48 W
  28. Emergency switch-1 unit
  29. Power : 24 VDC
  30. Type :Mushroom
  31. Contact : 1a 1b
  32. Contact load: Max. 8 A
  33. Inductive sensor-1 unit 
  34. Switching power : DC 10 – 30 V
  35. Switching distance : 5 mm
  36. Switching frequency: max. 800 Hz
  37. Output contact : NO contact, PNP
  38. Output current : max 400 mA
  39. Capacitive sensor-1 unit
  40. Switching power : DC 10 – 30 V
  41. Switching distance : 8 mm
  42. Switching frequency: max. 100 Hz
  43. Output contact : NO contact, PNP
  44. Output current : max 400 mA
  45. Switching capacity : 4.8 W
  46. Optical sensor-1 unit
  47. Switching power : DC 10 – 30 V
  48. Switching distance : 200 mm
  49. Switching frequency: max. 800 Hz
  50. Output contact : NO contact, PNP
  51. Output current : max 400 mA
  52. Pressure switch -1 unit
  53. Diaphragm switch
  54. Operating pressure : 10 – 70 bar
  55. Hysteresis : app. 15 %
  56. Max. load rate : 5 A
  57. Manual operating
  58. 4/2-way solenoid valve-1 unit
  59. Pressure range : 0 – 120 bar
  60. Operating pressure : 60 bar
  61. Power consumption : 12 W
  62. Power : 24V DC
  63. LED and protection circuit
  64. 4/3-way double solenoid valve with relieving mid-1 unit
  65. position (ABT connected)
  66. Pressure range : 0 – 120 bar
  67. Operating pressure : 60 bar
  68. Power consumption : 12 W
  69. ABT connected
  70. Power : 24V DC
  71. LED and protection circuit
  72. 4/3-way double solenoid valve with recirculating-1 unit
  73. mid position (PT connected)
  74. Pressure range : 0 – 120 bar
  75. Operating pressure : 60 bar
  76. Power consumption : 12 W
  77. PT connected
  78. Power : 24V DC
  79. LED and protection circuit
  80. Double acting cylinder-1 unit
  81. Pressure range : 0 – 120 bar
  82. Operating pressure : 60 bar
  83. Diameter : 25 mm
  84. Rod diameter : 18 mm
  85. Cylinder stroke : 200 mm
  86. Workbook – Advanced Electro-Hydraulics-1 unit English
  87. Training at site for 2 days 
  88. Warranty- 2 years warranty against manufacturing defects

Enquiry Form