CENTRIFUGAL PUMP MODULE

Order Code: 22235750.35

Category: General Lab Equipment II

Key Features Centrifugal pump mounted in a mobile frame with full instrumentation Part of Modular Fluid Power range that connects with the Universal  Dynamometer as a common motive power source for a cost-effective solution Allows...



SPECIFICATION

Key Features

  • Centrifugal pump mounted in a mobile frame with full instrumentation
  • Part of Modular Fluid Power range that connects with the Universal  Dynamometer as a common motive power source for a cost-effective solution
  • Allows students to study and test a popular fl uid power machine
  • Inlet and delivery valves for a wide range of operating conditions
  • Connection plate with schematic diagram clearly shows the water fl ow circuit and how  parts of the module connect to each other
  • Fully variable speed, for a range of test results
  • Turbine dynamometer and turbines (available separately): propeller, Francis and Pelton
  • Includes digital pressure display
  • Can connect to Versatile Data Acquisition System 

Description
For use with and driven by the Universal Dynamometer , the Centrifugal Pump Module is part of Modular Fluid Power range. The Centrifugal Pump Module is ideal for student experiments, demonstrations and projects. Centrifugal pumps are common machines used to move water and other fluids in many applications. These can be domestic water systems, agriculture, sanitation and many industrial applications. The module includes a centrifugal pump, a Venturi flow meter, valves, a reservoir and instrumentation; all mounted on a robust, mobile trolley for ease of use.

The separate Universal Dynamometer measures and displays the speed and torque of the pump to calculate and display mechanical (shaft) power. Electronic pressure transducers measure the pump inlet and delivery pressures and the Venturi diff erential pressure (flow rate).

Speed is fully variable up to the maximum allowable for the pump. The centrifugal pump is also the power source for the optional turbines: a Pelton wheel, a Francis turbine and Propeller turbine (all available separately). The turbines fit on the separate Turbine Dynamometer . You can only test one turbine at a time. The Turbine Dynamometer fi ts onto the Centrifugal Pump Module. The centrifugal pump delivery pipe then connects to the turbine.

A pressure transducer on the Centrifugal Pump Module measures the turbine inlet pressure. The turbines and Turbine Dynamometer allow students to test three diff erent turbines to find how they work and perform. When used with an optional stroboscope, students can ‘freeze’ the image of the moving turbines and water flow to improve their understanding of the turbines.For quick and reliable tests, can supply the optional Versatile Data Acquisition System  gives accurate real-time data capture, monitoring and display, calculation and charting of all the important readings on a computer (PC is not supplied).
Standard Features

  • Supplied with comprehensive user guide
  • Five-year warranty
  • Made in accordance with the latest European Union directives

Learning Outcomes

  • Centrifugal pump performance and characteristics, typically head against fl ow and  efficiency against flow
  • Variation of pump performance with inlet pressure
  • Variation of pump performance with speed
  • Non-dimensional performance characteristics
  • Flow measurement using a Venturi Available Experiment Modules

Note: The following products require a Turbine
Dynamometer 

  • Pelton Wheel 
  • Propeller Turbine 
  • Francis Turbine 

Essential Base Unit

  • Universal Dynamometer 

Recommended Ancillaries

  • Versatile Data Acquisition System (frame-mounted version)
  • Stroboscope 

Essential Services
Electrical supply (for the Universal Dynamometer):

Single-phase, 220 - 240 VAC, 50/60 Hz, 20A
o r
Two-phase 220 - 240 VAC, 50/60 Hz, 20 A, WITH NEUTRAL
Water supply:
Self-contained water circuit: needs approximately 200 litres of cold, clean water
Floor space needed:
2 m x 1.5 m
Operating Conditions
Operating environment:

Laboratory
Storage temperature range:
–25°C to +55°C (when packed for transport)
Operating temperature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C
Specifications:
Is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specifi cation without prior notice.
Nett dimensions:
1800 mm x 1670 mm x 800 mm
Packed dimensions:
2.25 m3
Nett weight:
172 kg
Packed weight:
Approximately 250 kg
Power :
1.5 kW (from Universal Dynamometer)
Maximum pump speed:
2800 rev.min–1
Maximum flow rate:
4 L.s–1 (nominal)
Maximum delivery pressure:
2.5 Bar (nominal)
Instruments and measurements: 

  • Pressures: transducers and digital displays
  • Flow: Venturi and diff erential pressure transducer
  • Torque, speed and power: Measured and displayed digitally by the Universal Dynamometer 

Note: Outlets on the back of the motor drive of the Universal Dynamometer electrically 
power the digital displays.

Enquiry Form