Biomedical Trainer Kit

Order Code: 23246783.10

Category: General Lab Equipment II

Bio Medical Measurement System Having  Electro cardiogram ,  Electromyogram,Electrooculogram,Blood  pressure, photo plethysmogram, respiratory,  Ventilation Detection , Pluse Meter,Body  Impedence Detection Modul...



SPECIFICATION

  • Bio Medical Measurement System Having 
  • Electro cardiogram , 
  • Electromyogram,Electrooculogram,Blood 
  • pressure, photo plethysmogram, respiratory, 
  • Ventilation Detection , Pluse Meter,Body 
  • Impedence Detection Modules
  • Main Unit:
  • Function Generator
  • Output Waveform: Sine, Square and Triangle
  • Frequency Range: 0.01Hz ~ 1MHz, continuously adjustable
  • Amplitude Range: 50mVpp ~ 18Vpp (open circuit)
  • DC Offset: - 10V to +10V
  • Display: 4-digit, 7-segment display
  • Interface
  • Port USB Interface: Type B
  • Input Indicators IN1, IN2, IN3, IN4, IN5 
  • LEDs, indicating the corresponding 
  • connection for students when conducting 
  • experiments of ECG, EMG, EOG, EEG and body impedance.
  • Reset Switch for MCU reset
  • Select Switch for selection of the modules
  • LCD Status Display
  • Display the output frequency of the function generator
  • Display the module selectedDisplay Heart Rates, Respiration, Pulse Rates and Doppler Ultrasound Blood
  • PE Office
  • BNC Adaptor Connector for 2mm sockets /
  • BNC sockets
  • Module Output DB9 connector
  • List of Module:
  • Electrocardiogram ECG Module
  • Limb lead inputs
  • Limb electrode
  • limb leads: Lead I, Lead II, Lead III, aV , aV , aV
  • solation circuit
  • Gain: 100~5000
  • Band-pass filter: 0.1~100Hz
  • 1 output ECG signal
  • Electromyogram EMG Module
  • Surface electrode
  • Gain: x 1000, x 2000
  • Isolation circuit
  • Band-pass filter: 100 ~1000Hz
  • 2 outputs: Electromyogram signal and 
  • Muscle force signal
  • Electrooculogram EOG Module
  • Surface electrode
  • Gain: 5~3000
  • Isolation circuit
  • Band-pass filter: 0.05~30Hz
  • 2 outputs: Horizontal signal, Vertical signal
  • Electroencephalogram EEG 
  • Module
  • EEG electrode
  • Gain: 50~5000
  • Isolation circuit
  • Band-pass filter: 1~20Hz
  • 1 output EEG signal
  • Blood Pressure Measurement 
  • Module
  • Pressure transducer:
  • Differential pressure model
  • Pressure range: 0~5 psid
  • Accuracy: 0.5%
  • Input impedance : 5K
  • Pressure calibration circuit
  • Gain amplifier : 20~800
  • Band-pass filter : 0.3~3Hz
  • 2 outputs: Cuff pressure signal, 
  • Oscillometric pulse signal
  • Photoplethysmogram Module
  • Infrared light-emitting diode
  • Rated forward current IF = 60mA
  • Rated reverse voltage VR = 4V
  • Peak wavelength λp = 880nm
  • Δθ = ± 53deg
  • Phototransistor
  • Rated C-E voltage VCEO = 20V
  • Rated collector power Pc = 75mW
  • Peak wavelength λp = 800nm d. Δθ = 50deg.
  • Gain: x 50~500, x 100~1000
  • Band-pass filter: 0.3~40Hz
  • 2 outputs: Plethysmogram signal, Heart ratepulse
  • Respiratory Ventilation Module
  • Temperature sensor
  • Thermistor: 5K (at 25°C)
  • Tolerance: ±5%
  • With temperature compensation circuit
  • Gain: 20
  • outputs: Pneumograph signal and 
  • Respiratory rate pulse
  • Pulse Meter Module
  • Strain gauge 5 mm grid, 120
  • Gain: x 2500, x 5000
  • Band-pass filter: 0.05 ~ 40Hz
  • outputs: Pulse wave and Heart rate pulse
  • Impedance Module
  • Band-pass filter: 0.1~10Hz
  • Sine wave generator circuit: 50KHz
  • Surface electrode
  • Isolation circuit
  • Gain: x 1250, x 2500
  • With over current protection and reset circuits
  • output Body impedance signal
  • Doppler Ultrasound Blood 
  • Velocity Module
  • Dual Element Transducer Frequency: 5MHz
  • Gain: 16~100
  • Band-pass filter: 1~40Hz
  • Outputs: Plethysmogram signal and Heart rate pulse
  • TENS Module
  • Electrode lead
  • Output 555 Timer-Astable signal
  • Frequency Adjust: 25~115Hz
  • Duty Cycle: 91~98%
  • Respiration Flow/Vital Capacity 
  • Meter Module
  • Pneumotach transducer
  • Excitation voltage: 6V
  • Flow range: 2-35L/min
  • Resolution: 700P/L
  • Maximum operation pressure: 25 Bar
  • Outputs: Respiration flow signal and 
  • Counting pulse. Installation & Commissoning
     

Enquiry Form