Order Code: 23246730.10
Category: General Lab Equipment II
Fixed DC power supply (1) Output voltage : +5V, -5V, +12V, -12V (2) Max. output current : +5V/3A, -5V/0.3A, +12V/1.5A, -12V/0.3A (3) With output overload protection
Specifications:
Main Unit
1. Power Supply Unit
Fixed DC power supply
(1) Output voltage : +5V, -5V, +12V, -12V
(2) Max. output current : +5V/3A, -5V/0.3A, +12V/1.5A, -12V/0.3A
(3) With output overload protection
2. A/D Converter : 1x12-bit ADC
V-,V+ input, Vo output, adjustable gain
Experiment Modules
1. Using 2mm plugs and sockets
2. Comprehensive experiment manual
3. Modules secured in plastic housings
4. Connected by 2mm-2mm test leads
5. Dimension : 255 x 165 x 30mm
6. Circuit symbols, blocks and components printed on the surface of each module
7. Power supplied from KL-61001B main unit
Graphic User Interface Software
System Requirements
1. PC: 1GHz or faster 32-bit (x86) or 64-bit (x64) processor, 1GB RAM, 1 GB more free disk space
2. Operating System : XP/ Vista/ 7/8/10
Specification & Feature
1. Real-time acquire signal
2. Adjustable acquire frequency
3. Current, Min, and Max values displayed
4. Data save, load and print function
5. X-axis: TIME/DIV
Y-axis : VOLT/DIV
6. Storage format: Excel format
List of Modules
KL-64001A
1. Phototransistor
2. Photo interrupter
3. Magnetic (hall-effect) ~ digital
4. Magnetic (hall-effect) ~ analog
KL-64002
1. Pyroelectric detector
2. Reed switch
3. Thermistor
4. Mercury switch
KL-64003A
1. Limit switch
2. Vibration switch
3. Condenser microphone
4. Dynamic microphone
KL-64004
1. Gas/smoke sensor
2. Ethanol sensor
KL-64005A
1. IC (AD590) temperature sensor
2. Humidity sensor
(1) Humidity transducer rated voltage: 1 Vp-p AC
(2) Frequency range: 100Hz ~ 10KHz
(3) Temperature range : 0°C ~ 60°C
(4) Humidity range: 20%RH ~ 90%RH
(5) Impedance : 13KΩ (70%RH at 25°C)
KL-64006
1. Infrared TX / RX sensor
(1) Infrared transmitter: Emission intensity: 12mW/sr
(I = 50mA)
Emission wavelength: 940nm
(IF = 50mA)
(2) Infrared receiver: Sensitivity wavelength: 1000nm
2. Ultrasonic TX / RX sensor
Nominal frequency: 40KHz
KL-64007A
1. Pressure sensor
0-7 psi to 0-30 psi pressure ranges
2. Strain gauge
(1) Maximum payload: <5kg
(2) Terminal resistance: 350 ± 50Ω
KL-64008
1. Hall current sensor
(1) Nominal current: ±3A
(2) Current range: ±9A
(3) Output voltage : ±4V, RL = 10 k Ohms
2. Proximity sensor
(1) Operation voltages: 10 ~ 30V DC
(2) Short circuit protection
KL-64009
1. CDS sensor
2. Photovoltaic sensor
(1) Photovoltaic transducer open voltage = 2V
(2) Photovoltaic transducer close current = 0.06 μA/lx
KL-64010
1. V/F converter
(1) Input voltage: +10mV ~+10V
(2) Output frequency : 5Hz ~ 5KHz, 10Hz ~10KHz
KL-64011
1. F/V converter
(1) Input frequency : 0 ~ 4.3KHz ( ±0.2Vp ~ ±5Vp)
(2) Output voltage : 0 ~ 4.3V DC
KL-64012
1. RTD (PT-100)
(1) 0°C : 100Ω , 100°C : 139.16Ω
(2) Rating: 250°C
KL-64013
1. Level (Water)
Simulation of the reservoir control status (motor included)
KL-64014
1. Fiber optic emitter
(1) Forward current, DC (lF): 50mA
(2) Peak wavelength : 950nm
(3) Output power: 50μw
2. Fiber optic phototransistor
(1) λpeak: 850nm
(2) Collect current (LC) : 50mA
(3) Power dissipation: 100mw
KL-64015
1. LVDT
(1) Range: ±5mm
(2) Scale: 0.01mm
(3) Optimum frequency : 50Hz ~ 1.1KHz; (Nominal : 350Hz)
KL-64016
1. Rotation angle sensor
(1) 10 turns (3600°) precision potentiometer
(2) Linearity: ± 0.25%
List of Experiments
D/A and A/D Converters
Characteristics of Sensors
Gas Sensors
AD590 Temperature Transducer
Hall Current Sensor
PT100 Temperature Sensor
Humidity Sensor
Strain Gauge
Linear Variable Difference Transformer (LVDT)
Photovoltaic Cell
Proximity Switch
Infrared Transducer
Ultrasonic Transducer
Pressure Sensor
V/F and F/V Converters
CDS Cell
Accessories
1. Experimental manual
2. Connection leads and plugs: 1 set
Level Controller
Fiber Optical Communication
Rotation Angle Sensor.