Analog Oscilloscope

Order Code: 23246435.5

Category: General Lab Equipment II

Features 100MHz Bandwidth, Dual Channel, Delayed Sweep 10 Sets Memory for Front Panel Setting Save & Recall Time Base Auto-range Cursor Readout with 7 Measurements Panel Setup Lock of Digital-Control Functions Buzzer Alarm LED I...



SPECIFICATION

Features

  • 100MHz Bandwidth, Dual Channel, Delayed Sweep
  • 10 Sets Memory for Front Panel Setting Save & Recall
  • Time Base Auto-range
  • Cursor Readout with 7 Measurements
  • Panel Setup Lock of Digital-Control Functions
  • Buzzer Alarm
  • LED Indicators
  • TV Synchronization
  • Trigger Signal Output
  • Z-Axis Modulation Input
  • SMD Technology, High Stability and Reliability
  • Specifications
  • CRT
  • Type 6-inch rectangular type with internal graticule
  • 0%, 10%, 90% and 100% markers
  • 8 x 10 div (1 div = 1 cm)
  • Accelerating Potential 16 kV approx
  • Illumination Continuously adjustable
  • Z-axis input Coupling : DC
  • Sensitivity: 5V or more
  • Maximum input voltage : 30V (DC + AC peak) at 1kHz 
  • Bandwidth : DC ~ 5 MHz

Vertical System

  • Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence
  • Sensitivity Accuracy 3% (5 div at the center of display)
  • Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less of panel-indicate value
  • Bandwidth(-3dB) DC~100MHz(2mV/div:DC~20MHz)
  • Rise Time 3.5ns (2mV/div:17.5ns)
  • Signal Delay Leading edge can be monitored
  • Max. Input Voltage 400V(DC+AC peak) at 1kHz
  • Input Coupling AC, DC, GND
  • Input Impedance 1MÙ±2% // approx. 25pF
  • Vertical Mode CH1, CH2, DUAL(CHOP/ALT), ADD, CH2 INV.
  • Bandwidth Limited 20MHz
  • Common-Mode Rejection Ratio 50:1 or better at 50kHz
  • Dynamic Range 8 div at 100MHz

Horizontal System

  • Horizontal Modes
  • MAIN(A), ALT, DELAY(B)
  • A(main) Sweep Time 50ns~0.5s/div, continuously variable (UNCAL)
  • B(delay) Sweep Time 50ns~50ms/div
  • Accuracy ±3% (±5% at x 10 MAG)
  • Sweep Magnification x 10 (maximum sweep time 5nS/div)
  • Hold Off Time Variable
  • Delay Time 1µs~5s
  • Delay Jitter Better than 1:20000
  • Alternate Separation Variable

X-Y Operation Mode

  • X-axis: selectable CH1, CH2, EXT
  • Y-axis: selectable CH1, CH2, CH1 and CH2
  • Sensitivity Accuracy 2mV~5V/div±3% ; EXT : 0.1V/div±5%
  • X-axis Bandwidth DC~500kHz(-3dB)
  • Phase Error 3° or less from DC~50kHzOUTPUT 

Signal

  • Trigger Signal Output
  • Voltage: approx. 25mV/div into 50Ù
  • Frequency response : DC ~ 10MHz
  • Calibrator Output 1kHz Squarewave, 2Vpp±2%

Cursor Readout Function 

  • Cursor Measurement Function ÄV, ÄV%, ÄVdB, ÄT, 1/ÄT, ÄT%, Äè 
  • Cursor Resolution 1/100 DIV
  • Effective Cursor Range Vertical: ±3div ; Horizontal: ±4 div
  • Panel Setting Display Vertical: V/div(CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
  • Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , HO
  • Trigger: source, coupling, slope, level, TV-V, TV-H
  • Others: X-Y, lock, save/recall MEM 0-9

Special Function 

  • TIME/DIV Auto Range Provided Panel Setting Save & Recall 10 sets Panel Setups Lock Provided
  • Power Source AC: 100V/120V/230V±10% , 50/60Hz

Accessories 

  • Instruction manual x 1
  • Power cord x 1
  • GTP-100A-2: 100MHz (10:1/1:1) Switchable Passive 
  • Probe (one per channel)
  • DIMENSIONS & WEIGHT 310(W) x 150(H) x 455(D) mm
  • Approx. 9Kg
     