Quantity Specifications 1 Measuring inputs 9 ALMEMO® input sockets, Electrically isolated with semiconductor relay (50 V) A/D converter Delta-si...



SPECIFICATION

Quantity

Specifications

1

Measuring inputs

9 ALMEMO® input sockets, Electrically isolated with semiconductor relay (50 V)

A/D converter

Delta-sigma 24-bit, 50 mea. op. p. sec., electrically isolated.

Sensor power supply

-Rechargeable battery 9 or 12 V, maximum. 100 mA

-Mains adapter 12 V, maximum. 100 mA

Outputs

2 ALMEMO® sockets for all output modules (analog, data, trigger, relay cables, memory, etc.)

Standard equipment

-Display: Graphics, 128x128 pixels, 16 rows

Lighting: 5 white LEDs, 3 levels

-Keypad: 9 membrane keys (4 soft-keys), thumb-wheel

-Memory: 512-KB EEPROM (100,000 meas. values)

-Date and time-of-day: Real-time clock, buffered with battery

Power supply

-Rechargeable batt. pack 6 NMH rechargeable batteries, 1600 mA

2.5-hour high-speed charging,

internal circuit

- Mains adapter: 230V AC to 12 V DC, 1A, electrically isolated

-DC adapter cable: electrically isolated 10 to 30 V, 1 A

- Current consumption without input and output modules:

Active mode approx. 37 mA with lighting approx. 45 to 100 mA. Sleep mode approx. 0.05 mA

Housing

(LxWxH) 204 x 109 x 44 mm

ABS (maximum 70 °C), 550 g

 

Calibration software

AMR-Control software MA28909

Option KL :Multi-point calibration, special ranges

 

ALMEMOManual, manufacturer’s test certificate,

 

Calibration certificate of each parameter (atmospheric pressure, humidity and air temperature

 

Mandatory accessories

  1. DC adapter cable: 10 to 30 V DC, 12 V / 1 A, electrically isolated

  2. Memory connector with MMC card, including USB card reader

  3. Analog output cable, 1.25 to 2.0 V, 0.1 mV / digit

  4. Trigger and alarm cable: (2 relays, 1 ohm, 300 mA, 50 V)

  5. V24 data cable, electrically isolated, max. 115.2 KB

  6. Ethernet data cable, electrically isolated, max. 115.2 KB

  7. Network cable, electrically isolated, max. 115.2 KB

  8. Transport case, large (aluminum),

  9. Pressure sensor:

Measuring range:700 to 1050mbar

Overload:max.1.5 fold of fin.cal range

Accuracy:±0.5% of final value

Operating range:-10 to +600c;10 to 90%H non condensing

Dimensions:90*20*7.6mm (MINIMUM)

Hose connection:Ø5mm,12mm long

Sensor material:aluminium

Connecting cable:0.2m

Extension cable:2m

  1. Water temperature sensor ( 2 Pieces)

Item name :Resistant thermometer

Measuring element:Pt100 4L, DIN class B

Options:DIN class A, 1/5 DIN class B

Sensor tip: Diameter d1 Sensor tip: 3.2 mm

Operating temp. Sensor tip: -40 to 500°C

Length L: 250 mm, material: stainless steel

Diameter d2, Sheathed line:2.8 mm

Cable sleeve: Brass, hexagonal, L = 65 mm, circum diameter = 9 mm, operating temp. –40 to +160 °C

Standard cable:1.5 meters line, FEP / silicone, insulated, operating temperature –50 to +200 °C

Cable options: Line, PVC / PVC, insulated, operating temperature –20 to +105 °C

  1. Air temperature and humidity sensor

Humidity

Measuring range 5 to 98 % RH

Accuracy ±2.0 % RH in range 10 to 90 % at nominal temperature Hysteresis typical ±1 % RH

Nominal temperature +23 °C ±5 °C

Sensor operating pressure Atmospheric pressure

Response time T63typical 8 seconds at +25 °C, 1 m/s(without filter)

 

Temperature

Sensor NTC Type N

Operative range -20 to +60 °C

Accuracy typical ±0.2 K at 5 to 60 °C

maximum ±0.4 K at 5 to 60 °C

maximum ±0.7 K at -20 to +80 °C

Reproducibility typical ±0.1 K

Response time T63typical 20 seconds (without filter)

Standard cable(connecting cable):1.5 meters line, FEP / silicone, insulated, operating temperature –50 to +200 °C