Advanced sensor experimental system Equipment

Order Code: 24257748.13

Category: General Lab Equipment V

Features: Industrial-standard sensors and transducers With USB interface Open-ended design, ideal for expansion Offer a sensing data acquisition software Specification Sensor Main Unit 1. Power Supply Unit Fixed DC...



SPECIFICATION

Features:

  1. Industrial-standard sensors and transducers With USB interface

  2. Open-ended design, ideal for expansion

  3. Offer a sensing data acquisition software

Specification
Sensor Main Unit
1. Power Supply Unit
Fixed DC power supply
(1) Output voltage : +5V, -5V, +12V, -12V
(2) Max. output current : +5V/3A, -5V/0.3A, +12V/1A, -12V/0.5A
(3) With output overload protection
2. A/D Converter : 1x12-bit ADC
(1) Input voltage range : 0 ~ +5V
(2) Time pulse frequency : 3.58MHz
(3) Control signals : status, pole, over range indication
3. Interface Port
USB interface : type B
4. D/A Converter : 1 x 12-bit DAC
Analog output & control
OUT+ : +DC OFFSET 0 ~ +4.096V unipolar
OUT- : -DC OFFSET 0 ~ - 4.096V unipolar
OUT BP : DC OFFSET -2.048V ~ +2.048V bipolar
5. Preset Level : 4-digit thumbwheel switch, Max. value : 4095
6. Status Display & DCV
Input voltage measurement
(1) Range : 2000mV, 20V
(2) Accuracy : ±0.05% of reading + 4 counts
(3) Input impedance : 10M ohms
(4) Display : 4 1/2 digits
7. Mode Selector : manual/single-chip
8. Buzzer : Max. input signal voltage : +12V
9. Micro Controller Signals : 5 control line outputs
10. Model Holder : X4
11. Potentiometer : 100K ohms B-type
12. Comparator : V-, V+ input, Vo output
13. Differential Amplifier : V-, V+ input, Vo output
14. Instrumentation Amplifier : V-, V+ input, Vo output, adjustable gain
Experiment Modules
1. 2mm plugs and sockets used throughout
2. Comprehensive experiment manual
3. Modules secured in plastic housings
4. Connected by 2mm-2mm test leads
5. Dimension : (255 x 165 x 30)mm
6. Circuit symbols, blocks and components printed on the surface
of each module
7. Power supplied from either power module or through main unit
Graphic User Interface Software
System Requirement
1. PC : 1GHz or faster 32-bit (x86) or 64-bit (x64) processor, 1GB
RAM, 1GB more free disk space
2. OS : Windows XP/Vista/7/8/10
Specifications & Features
1. Real time acquire signal
2. Adjustable acquire frequency
3. Current, Min and Max value displayed
4. Data save, load and print function
5. X-axis : TIME/DIV
Y-axis : VOLT/DIV
6. Storage format : excel format
List of Modules
1. General Sensor Module
2. General Transducer Module
3. AD590 Transducer Module
4. Thermocouple Transducer Module
5. PT100 Temperature Transducer Module
6. Humidity Transducer Module
7. Load-Cell Transducer Module
8. LVDT Transducer Module
9. Photovoltaic Transducer Module
10. Counter Module
11. Linear Scale Module
12. Infrared Transducer Module
13. Multi-Channel Remote Controlled Module
14. Ultrasonic Transducer Module
15. Pressure Transducer Module
16. VFC Module
17. FVC Module
Load Units
1. Humidity & Temperature Load
(1) Temperature load
a. Provides heat source for AD590, PT-100 and thermocouples
b. Temperature range : ambient ~ 170 degree Celsius
c. Manual/automatic selection
d. Insulated for safety reasons
e. Digital temperature control : SSR driven voltage output
f. ON/OFF LED indicator
(2) Humidity Load
a. Provides humidity source for Humidity Transducer
b. Humidity Range : ambient ~ 99% RH
c . Stainless steel tray for water storage
d. With a humidity / temperature switch
e. With humidify / dehumidify functions
2. Pressure Gauge
(1) Pressure gauge : full scale 5000mm Ag
(2) Flow rate control valve
(3) Power source : 110V/220V AC
3. Load Cell
(1) Construct strain gauge and bridge circuit
(2) Max. load : < 5Kg
(3) Electronic scale
4. Linear Variable-Differential Transformer (LVDT)
(1) Range : ±5mm
(2) Scale : 0.01mm
(3) Linear accuracy : 0.1%
(4) Excitation frequency : 350Hz
5. LUX Load
(1) Selectable light sources
(2) Light bulb luminous intensity adjustable
(3) Photovoltaic transducer open voltage : about 2V
(4) Photovoltaic transducer close current : about 0.08μA/lx
6. Angle/Distance Load
(1) Platform moving range : 300mm
(2) Adjustable transmitting/receiving angle : 30 degree/step, 0 ~
360 degree
(3) Infrared receiver : Max. input wavelength = 940nm
(4) Ultrasonic transmitter/receiver : nominal frequency = 40KHz
7. Linear Scale
(1) Resolution : 0.005mm
(2) Max. range : 200mm
(3) Stepping motor with speed adjustment
(4) Voltage requirement : +5V DC
(5) Left/right directional switch
(6) Left/right limit switch
8. Standard Weight Set
2 x 50g, 2 x 100g, 1 x 200g, 1 x 500g, 2 x 1Kg, 1 x 2Kg
9. Encoder Sensor Module
(1) DC power supply : +5V DC
(2) Output signal : A, B, Z
(3) Max. pulse frequency : 30KHz (300P/R)
(4) Max. speed : 6000rpm (300P/R)
Equipment Required
1. Power Supply
2. Power Supply (0 ~ ±30V/3A)
3. Computer Servicing Tool Kit
4. Alcohol Prep Pad
5. Digital Storage Oscilloscope (DSO) : 100MHz bandwidth, 1GS/s
sampling rate and FFT function or better
6. Hand-held Digital Multimeter
7. Thermometer
8. Function Generator
9. Frequency Counter
Accessories
1. Experimental Manual
2. Connection Leads and Plugs
3. Magnet
Required Document:
- Manufacturers Authorization Letter must be Submit.
-Catalog must be Submit.
-Installation, Testing, and Commissioning, mandato
 

Enquiry Form