Advanced Sensor Experimental System

Order Code: 22236121.4

Category: General Lab Equipment II

Sensor Main Unit Power Supply Unit Fixed DC power supply Output voltage : +5V, -5V, +12V, -12V Max Output current : +5V/3A, -5V/0.3A, +12V/1A, -12V/0.5A  With output overload protection A/D Converter : 1x12-bit ADC Input volta...



SPECIFICATION

Sensor Main Unit

  • Power Supply Unit Fixed DC power supply
  • Output voltage : +5V, -5V, +12V, -12V Max
  • Output current : +5V/3A, -5V/0.3A, +12V/1A, -12V/0.5A  With output overload protection
  • A/D Converter : 1x12-bit ADC
  • Input voltage range : 0 ~ +5V
  • Time pulse frequency : 3.58MHz
  • Control signals: status, pole, over range indication
  • Interface Port,USB interface : type B
  • D/A Converter : 1 x 12- bit DAC Analog output& control,OUT+ : +DC OFFSET 0 ~ +4.096V unipolar,OUT- : -DC OFFSET 0 ~ - 4.096V unipolar,OUT BP : DC OFFSET -2.048V ~ +2.048V bipolar
  • Preset Level : 4- digit thumbwheel switch, Max. value : 4095
  • Dimension : (255 x 165 x 30)mm,Graphic User Interface Software

System Requirement

  • PC : 1GHz or faster 32-bit (x86) or 64-bit (x64) processor, 1G RAM, 1GB more free disk space
  • OS : Windows XP/Vista/7/8/10,. Data save, load and print function,. X-axis : TIME/DIV,Y-axis : VOLT/DIV, Storage format : excel format

List of Modules

  • General Sensor Module
  • General Transducer Module
  • AD590 Transducer Module
  • Thermocouple Transducer Module
  •  PT100 Temperature Transducer Module
  • Humidity Transducer Module
  • Load-Cell Transducer Module
  • LVDT Transducer Module
  • Photovoltaic Transducer Module
  • Counter Module
  • Linear Scale Module
  • Infrared Transducer Module
  • Multi-Channel Remote Controlled Module
  • Ultrasonic Transducer Module
  • Pressure Transducer Module
  • VFC Module
  • FVC Module

List of Experiments

  • D/A and A/D Converters
  • Characteristics of Sensors,Photo transistor,Photo interruptor, Magnetic sensor, Pyroelectric detector,Thermistor,Reed switch, Inclination sensor,Limit switch,Mercury switch,Vibration switch, Condenser microphone, Dynamic microphone,General-Purpose Transducers, Gas/smoke detector, Ethanol detector,Digital magnetic detector,Analog magnetic detector Humidity Transducer, Impedance characteristic of humidity sensor, Transduction circuit of humidity sensor,The application of humidity sensor - Digital hygrometer, Load-Cell, Linear Variable Differential Transformer (LVDT),Characteristics of LVDT, Photovoltaic Cell,Photovoltaic characteristics,Linear Scale, Infrared Transducer,Ultrasonic Transducer, Pressure Transducer V/F and F/V Converters

Load Units

  • Humidity & Temperature Load,Provides heat source for AD590
  • PT-100 and thermocouples
  • Temperature range : ambient ~ 170 degree Celsius, Humidity Load, Provides humidity source for Humidity Transducer
  • Humidity Range : ambient ~ 99% RH
  • Pressure Gauge,Pressure gauge : full scale 5000mm Ag
  • Load Cell
  • LUX Load
  • Photovoltaic transducer close current : about 0.08µA/lx, Angle/Distance Load
  • Platform moving range : 300mm, Linear Scale
  • Resolution : 0.005mm
  • Max. range : 200mm, Standard Weight Set2 x 50g, 2 x 100g, 1 x 200g, 1 x 500g, 2 x 1Kg, 1 x 2Kg
  • Encoder Sensor Module
  • Max. speed : 6000rpm (300P/R)

Accessories

  • Experimental Manual
  • Connection Leads and Plugs
  • Magnet Training will be performed by qualified and experienced engineers including required raw materials at bidder own cost.1, Warranty: 01 year warranty with service
     

Enquiry Form