Turbine Pump Base Unit

Order Code: 32359

Category: Thermodynamics Lab

Pelton turbine and an action turbine. The well- structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments. Specifications: Supplying the turbines with water under pressure Basic experim...



SPECIFICATION

Pelton turbine and an action turbine. The well- structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.

Specifications:
Supplying the turbines with water under pressure
Basic experiments on centrifugal pumps
Together with the turbines: investigation of operating behaviour and recording of turbine characteristics
Includes pump and transparent water tank
Low air entry into circulating water ensured by damping plate inside the tank
Variable pump speed via frequency converter
Sensors for flow rate and pressure
Microprocessor-based measuring technique
Unit-specific software for data acquisition and operation via USB under Windows Vista or Windows

Features
Closed water circuit for supplying turbines
Software for data acquisition, visualization and operation
Basic experiments on centrifugal pumps
Part of the fluid energy machines

Tesca Turbine Pump – Base Unit is required to supply different turbines. Additionally, the base unit enables basic experiments on a centrifugal pump.

The closed water circuit of pump features a water tank and a centrifugal pump with variable speed via a frequency converter. The turbine to be investigated is placed on the tank cover and is connected to the base unit via a hose. The flow rate hence the pressure applied to the turbine is adjusted by pump speed. The head and the pressure upstream of the turbine can be kept constant by a pressure control. A damping plate inside the tank ensures a low air entry into the circulating water. Basic pump experiments can be performed using the throttle valve included. The throttle valve is placed upon the tank cover instead of the turbine.

The base unit is fitted with sensors for pressure and flow rate. The microprocessor-based measuring technique is well protected in the housing. All the advantages of software-supported experiments and evaluation are offered by the GUNT software and the microprocessor. The connection to a PC is made by USB.
Technical Specifications Pump
Power Consumption: 670w
Max. Flow Rate: 70l/min
Max. Head: 35,4m
Water Tank: Approx. 15l
Measuring ranges
Flow Rate: 3,9...50l/min
Pressure: -1...5bar

Experiment Capabilities
Basic experiments on a centrifugal pump together with the turbines
Determination of typical turbine curves
Performance curves at varying turbine speeds
Determination of efficiencies

Required Services:
Electric Supply 220 - 240V AC, 16 A, Single Phase, Earthed.

Following turbines are available: a reaction turbine, a