Order Code: 32079
Category: Fluid Mechanics Lab
Features: 2 interchangeable rotors1 Transparent delivery pipe and intake pipe1 Software for data acquisition, visualization and operation1 Radial fans are used to transport gases with non- excessive pressure differen...
Features:
2 interchangeable rotors1
Transparent delivery pipe and intake pipe1
Software for data acquisition, visualization and operation1
Radial fans are used to transport gases with non- excessive pressure differences. The medium is drawn axially to the drive shaft of the radial fan and is deflected by 90° by the rotation of the rotor and discharged radially.
Tesca Radial Fan test Apparatus the experimental unit provides the basic experiments to get to know the operating behavior and the most important characteristic variables of radial fans. features a radial fan with variable speed via a frequency converter, an intake pipe, and a delivery pipe. The transparent intake pipe is fitted with guide plates for flow guidance and with a flow straightener to calm the air. This enables precise measurements even with the heavily reduced operation.
The airflow is adjusted by a throttle valve at the end of the delivery pipe.
To demonstrate the effect of different blade shapes two rotors are included in the scope of delivery: one rotor with forwarding curved blades and one with backward curved blades. The rotors are easily interchangeable.
The experimental unit is fitted with sensors for pressure and temperature. The flow rate is determined via differential pressure measurement on the intake nozzle.
The microprocessor-based measuring technique is well protected in the housing. All the advantages of software-supported experiments and evaluation are offered by the software and the microprocessor. The connection to a PC is made by USB.
The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.
Specifications:
Functioning and operating behavior of a radial fan
Radial fan with 3-phase AC motor
Variable speed via frequency converter
Transparent intake and delivery pipes
Throttle valve to adjust the airflow in the delivery pipe
Interchangeable rotors: 1 rotor with forwarding curved blades and 1 rotor with backward-curved blades
Determination of flow rate via intake nozzle
Order Code - 32079
Display of differential pressure, flow rate, speed, electrical power consumption, and hydraulic power output, temperature, and efficiency
Microprocessor-based measuring technique
Optional unit-specific software for data acquisition and operation via USB under Windows Vista or Windows 7
Technical Specifications:
Intake pipe
Inner diameter: 90mm Ÿ Length: 430mm Delivery pipe
Inner diameter: 100mm
Length: 530mm
Radial fan
Power consumption: 110W Ÿ Nominal speed: 2800min-1 Ÿ Max. flow rate: 480m³/h
Max. differential pressure: 300Pa Displayed / measuring ranges
Differential pressure: 0...1800Pa
Flow rate: 0...1000m³/h Ÿ Temperature: 0...100°C Ÿ Speed: 0...3300min-1
Electrical power consumption: 0...250W
Experiments:
Operating behavior and characteristic variables of a radial fan
Recording the fan characteristic (differential pressure as a function of the flow rate)
Effect of the rotor speed on the pressure
Effect of the rotor speed on the flow rate
Effect of different rotor shapes on the fan characteristic and efficiency
Determination of hydraulic power output and efficiencies
Services Required:
Mains power supply: 220-240V, 1Ph, 50Hz