Domestic Hot Water System

Order Code: 32505

Category: Other Trainers

The main function of Domestic Hot Water System Order Code : 32505 is to provide a hot water circuit. To do this, the supply unit is equipped with a heated water tank and a pump for the hot water circuit, connections for the cold water inlet and a swi...



SPECIFICATION

The main function of Domestic Hot Water System Order Code : 32505 is to provide a hot water circuit. To do this, the supply unit is equipped with a heated water tank and a pump for the hot water circuit, connections for the cold water inlet and a switch cabinet with displays and controls. Heater heat the water in the water tank. A pump transports the heated water from the water tank through pipelines. Hot Water Heater facility has possibilities to connect three different types of heaters:
a) Geyser Type
b) Instant Type
c) Storage Type

The flow rate in the hot water circuit is adjusted by means of valves. The temperatures of the water in the flow pipe, in the return pipe and in the water tank are displayed. The flow rate is displayed by means of a rotameter. Two sight glasses indicate the lowest and the highest water level.

Specifications
Device for hot water supply
Main components: water tank with two heaters, pump
Two sight glasses for monitoring the level in the tank
Flow rate adjustable via valves
Flow measurement via rotameter
Measurement of temperatures in the feed and return, in the tank

Technical Specifications
Pump

max. flow rate: 1m3/h
max. head: 20m
Tank:
30L
Heater
Regular type
Output heater: 3kW max.

Measuring ranges
flow rate: 100-1000L/h
temperature: max. 80?

Options
Hot & Cold Water Mixer

Requirements
Water Source & Water Flushing system
Mains Power 220-240V@50Hz, 1 Phase