Order Code: 32435
Category: Refrigeration & Air Conditioning Lab
he purpose of a refrigeration system is the cooling of materials and products, e.g. to protect food from spoiling. Cooling can be described as a process in which heat is removed from the environment. A commonly used refrigeration system is the so-c
Features
The purpose of a refrigeration system is the cooling of materials and products, e.g. to protect food from spoiling. Cooling can be described as a process in which heat is removed from the environment.
A commonly used refrigeration system is the so-called compression refrigeration system. In this system refrigerant flows through four main elements: compressor, condenser, expansion element and evaporator. The refrigeration system uses the fact that the refrigerant has a low boiling point at low pressure. This means that evaporation takes place on the low pressure side. During the evaporation of the refrigerant heat is removed from the environment and it is cooled. The condensation takes place on the high pressure side after the evaporator. Here the heat is discharged into the environment. If not the cooling effect but the discharged heat is used, this is called a heat pump.
The set-up of Tesca Compression Refrigeration Circuit 32435 represents a simple compression refrigeration system. Evaporator and condenser have been designed as a pipe coil with each end immersed in a water-filled tank. The water simulates the environment. A thermostatic expansion valve serves as expansion element. Two manometers indicate the two system pressures on the high and low pressure sides. On an additional scale on the manometer the evaporation temperature of the refrigerant is indicated. Two thermometers measure the temperature of the water in the tanks.
This allows for calculations of the amount of heat removed from the environment (evaporator, cold water) and added to the environment (condenser, hot water). A sight glass indicates the aggregate state of the refrigerant upstream of the expansion valve.
The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.
Specifications
Technical Specifications
Compressor
- Power consumption: 104W at 5/40°C
- Refrigeration capacity: 278W at 5/40°C
- Displaced volume: 2,72cm³
Manometer with temperature scale for R134a
- Intake side (low pressure)
Pressure: -1...12,5bar
Temperature: -50...40°C
- Delivery side (high pressure)
Pressure: -1...25bar
Temperature: -40...80°C
Thermometer: 2x -10...50°C
Tank: 4x 1700mL
Experiments
Requirements
220 – 240V, 50Hz, 1 phase Power Supply