Order Code: 32118
Category: Fluid Mechanics Lab
Features: The wastewater treatment plant on a laboratory scale Aerobic biological degradation of organic substances Nitrification and pre-de-nitrification Tesca Activated Sludge Process Apparatus is the most...
Features:
Tesca Activated Sludge Process Apparatus is the most important biological process in water treatment. 32118 enables this process to be demonstrated.
A pump delivers raw water contaminated with dissolved organic substances (organic matter) into the aeration tank. Aerobic microorganisms (activated sludge) in the aeration tank use organic matter as a source of nutrition, biodegrading it in the process. Since aerobic microorganisms need oxygen, the raw water is aerated in the aeration tank. The activated sludge is mixed with the raw water by stirring machines. In the secondary clarifier, the activated sludge is then separated from the treated water by sedimentation. A portion of the activated sludge is returned to the aeration tank (return sludge). The treated water is collected in a tank.
It is also possible to convert ammonium into nitrate (nitrification) and nitrate into nitrogen (de-nitrification). For de-nitrification, a zone without aeration can be created in the aeration tank by installing a partition wall. The following flow rates are adjustable: raw water, return sludge, internal recirculation for pre-de nitrification, and air. Oxygen concentration, pH value, and temperature can be controlled. Optionally a software program can be provided to display the operation states and measure data. A process schematic shows the current operating states of the individual components and the measured data.
Samples can be taken at all relevant points. Activated sludge from a wastewater treatment plant and analysis technology is required for the experiments. Recommended parameters are:
- BOD5 (biochemical oxygen demand)
- COD (chemical oxygen demand)
- NH4 (ammonium)
- NO3 (nitrate)
Specifications:
Technical Specifications:
Aeration tank
Capacity nitrification zone: approx. 34L
Capacity de-nitrification zone: approx. 17L
Tanks
Secondary clarifier: 30L
Raw water tank: 200L
Treated water tank: 80L
Flow rates
Raw water pump: max. 25L/h
Return sludge pump: max. 25L/h
Circulation pump: max. 25L/h
Speeds (stirring machines)
Secondary clarifier: max. 45min-1
All others: each max. 600min-1
Measuring ranges
Flow rate:
2…25L/h (raw water)
50…550L/h (compressed air)
Temperature: 0…40°C
pH value: 0…14
Oxygen concentration: 0…10mg/L
Experiments:
Requirements:
Mains Power 220 – 240V @ 50Hz, 1Ph