Activated Sludge Process Apparatus

Order Code: 32118

Category: Fluid Mechanics Lab

Features: The wastewater treatment plant on a laboratory scale  Aerobic biological degradation of organic substances  Nitrification and pre-de-nitrification    Tesca Activated Sludge Process Apparatus is the most...



SPECIFICATION

Features:

  • The wastewater treatment plant on a laboratory scale 
  • Aerobic biological degradation of organic substances 
  • Nitrification and pre-de-nitrification 

 

Tesca Activated Sludge Process Apparatus is the most important biological process in water treatment. 32118 enables this process to be demonstrated.
A pump delivers raw water contaminated with dissolved organic substances (organic matter) into the  aeration tank. Aerobic microorganisms (activated sludge) in the aeration tank use organic matter as a  source of nutrition, biodegrading it in the process. Since aerobic microorganisms need oxygen, the raw  water is aerated in the aeration tank. The activated sludge is mixed with the raw water by stirring  machines. In the secondary clarifier, the activated sludge is then separated from the treated water by  sedimentation. A portion of the activated sludge is returned to the aeration tank (return sludge). The  treated water is collected in a tank. 

 

It is also possible to convert ammonium into nitrate (nitrification) and nitrate into nitrogen (de-nitrification).  For de-nitrification, a zone without aeration can be created in the aeration tank by installing a partition wall. The following flow rates are adjustable: raw water, return sludge, internal recirculation for pre-de nitrification, and air. Oxygen concentration, pH value, and temperature can be controlled. Optionally a software program can be provided to display the operation states and measure data. A  process schematic shows the current operating states of the individual components and the measured data. 
Samples can be taken at all relevant points. Activated sludge from a wastewater treatment plant and  analysis technology is required for the experiments. Recommended parameters are: 
- BOD5 (biochemical oxygen demand) 
- COD (chemical oxygen demand) 
- NH4 (ammonium) 
- NO3 (nitrate) 

 

Specifications:

  1. Biological wastewater treatment 
  2. Aeration tank with 3 stirring machines 
  3. Secondary clarifier 
  4. Nitrification and pre-de-nitrification 
  5. Separate supply unit with 2 stirring machines 
  6. All relevant flow rates adjustable
  7. Control of temperature, pH value, and oxygen concentration
  8. Measurement of flow rate, temperature, pH value, and oxygen concentration 
  9. Optional software for data acquisition via USB under Windows and display of the operation states & visual inspection  with a webcam on PC

 

Technical Specifications:
Aeration tank 
Capacity nitrification zone: approx. 34L 
Capacity de-nitrification zone: approx. 17L 
Tanks 
Secondary clarifier: 30L 
Raw water tank: 200L 
Treated water tank: 80L 
Flow rates 
Raw water pump: max. 25L/h 
Return sludge pump: max. 25L/h 
Circulation pump: max. 25L/h 
Speeds (stirring machines) 
Secondary clarifier: max. 45min-1 
All others: each max. 600min-1 
Measuring ranges 
Flow rate: 
2…25L/h (raw water) 
50…550L/h (compressed air) 
Temperature: 0…40°C 
pH value: 0…14 
Oxygen concentration: 0…10mg/L

 

Experiments:

  • Learning the fundamental principle of the activated sludge process 
  • Functional principle of nitrification and pre-de-nitrification 
  • Creation of a stable operating state 
  • Identification of the following influencing factors 
  • Return sludge ratio 
  • Return ratio of the internal recirculation 
  • Sludge age 
  • Sludge loading 
  • Volumetric loading 
  • Oxygen concentration, pH value, and temperature 
  • The efficiency of the pre-de-nitrification 

 

Requirements:
Mains Power 220 – 240V @ 50Hz, 1Ph 

Enquiry Form