6-liter Capacity Autocontrol Fermenter

Order Code: 21224500.8

Category: General Lab Equipment II

Technical details: Vessel: 6 L Working Volume: 1.1 - 4 - 0 L Dimensions (W x D x H): 455mm x 375mm x 740mm Drive: Version for Microorganisms: 150 min-1 to 1600 min-1 version for cell cultures: 24 min-1 to 600 min-1 Temperature + 10 °...



SPECIFICATION

Technical details:

  • Vessel: 6 L
  • Working Volume: 1.1 - 4 - 0 L
  • Dimensions (W x D x H): 455mm x 375mm x 740mm
  • Drive: Version for Microorganisms: 150 min-1 to 1600 min-1 version for cell cultures: 24 min-1 to 600 min-1
  • Temperature + 10 °C bis 60 °C
  • Gassing per vessel: Version for microorganism: 2 MFCs up to 2 min-1, version for cell cultures: 5 MFCs up to 0.15 min-1
  • Pumps per vessel: 4 x configurable (fixed or variable speed) ex-words: 3 x fixed (acid, base, anti-foam), 1 x variable (feed).
  • Pump performance: 0.0034 to 3,52 ml min-1 (standard), 0.017 to 16,13 ml min-1 0.0012 to 1.12 ml min-1
  • Ports per vessel: 7,5 mm - 4x, 10mm - 4x, 12 mm (Pg13,5) - max. 7x
  • Connectivity: OPC UA via Ethernet
  • Parallel opeartion via touch screen controller: 1 unit 
  • Sterilisation: Autoclave


Features:

  • Culture Vessel:
  • 6 L
  • Rounded flat vessel bottom: Low minimum working volume, good mixing, stability with or without a vessel holder
  • Safe sampling without any dead volume: INFORS HT Super Safe Sampler


Top Plate:

  • Intelligent design for easy access to all ports
  • Sufficient ports, for standard fittings and extra inlets, immersion tubes and sensors
  • 4 x 7.5 mm: addition ports available for acid, basde, feed & 1 free
  • 4 x 10mm: sparger, anti-foam system, temperature sensor, sampling/harvest
  • Maximum 7 x 12 mm (Pg13.5): pH, pO2, exhaust gas cooler, inoculation are pre-allocated, 3 are freely available
  • Convenient, tool-free cleaning and maintenance thanks to knurled screws


Gassing:

  • 2 integrated MFC for air, air/O2, or air/N2 (version for microorganisms)
  • 5 integrated MFC for air, O2, N2, CO2 and head space gassing (version for cell cultures)
  • Integrated pressure sensor for detecting a blocked filter
  • Gassing optimised for bacteria applications and cell cultures: specific gassing rate (vvm) up to 2.0 min-1
  • Multiple cascades for pO2 control by means of stirrer speed, gassing rate (''TotalFlow'') and/or gas composition (''GasMix'')


Sensor:

  • Strong, digital connection of pH and Po2 sensors
  • Optical pO2 sensor: immediately ready for use, no polarization required
  • Calibration data stored in sensor head
  • Product calibration of the pH sensor for reliable measurements during long-running bioprocesses
  • Operating unit
  • Integrated 7 touch screen (17.8cm) Simple handling through intuitive menus and practical on-screen help
  • Calibration of pH, pO2 and OD sensors using simple install wizards
  • Direct data export to USB drive in stand-alone operation
  • Multiple display languages
  • Bioprocess Platform


Software:

  • Planning, controlling and analysing bioprocesses
  • Integrated workflows, devices and bioprocess knowledge 
  • Integrates bioreactors and analytical instruments, regardless of the manufacturer
  • Web-based project organisation
  • Communication using the latest OPC UA (Minifors 2) or OPC XML-DA  standard (Multifors 2, Labfors 5, Techfors-S, Techfors)  Synchronisation of process-related events such as sampling or inoculation
     