230V AC input 24V DC, 32 outputs Traffic Signal Controller mounted in M.S powder coated Enclosure

Order Code: 23246363.8

Category: General Lab Equipment II

Features:- Auto / Manual Mode Operations: System Can Be Placed On ‘Manual Mode’ Operation As And When Desired By The User. This Mode Enables The Police To Control The Traffic According To The Traffic Volume At That Point Of Time F...



SPECIFICATION

Features:-

  • Auto / Manual Mode Operations: System Can Be Placed On ‘Manual Mode’ Operation As And When Desired By The User. This Mode Enables The Police To Control The Traffic According To The Traffic Volume At That Point Of Time
  • Flash Mode Operation: System Can Be Put Into “Flash Mode” Operation Whenever Needed By Activating The Switch Provided On The Police Panel. Provision Has Been Given To Activate The Flash Mode From Keyboard While In Programming Mode
  • Hurry Call: 8 ‘Hurry Call’ Plans Can Be Programmed. By Activating Hurry Call, All Running Signals Will Be Switched To Amber Plan For 4 Seconds And Then To Red Signal Except For The Activated Hurry Plan. Duration Of The Running Time Can Be Set For Each Hurry Call. Any Signal Plan Except 1 & 2 Can Be Configured As Hurry Call. Amber Plan Will Run On Completion Of The Hurry Call Operation Before Being Switched To The Signal Plan
  • All Red Plan: All Red Plan Is Executed Following Power On Of The System To Clear The Intersection Before Starting A Green Signal. Default Time Duration For “All Red Plan” Is 04 Seconds. This Can Be Increased Up To 99 Seconds If Desired By The User
  • Amber Plan: Amber Plan Is Activated During Manual Mode Operation Of The System. The Signal Plan Consisting Of Amber Output Will Be Automatically Changed To The Next Signal Plan After Running Predefined Time Of The Amber Output. Total Of 16 Entries Are Possible In This Plan
  • Line Test Plan: This Plan Is Used To Test The Physical Connection Of The Output From CPU To The Traffic Light Through Driver Card
  • MMI: Hand-Held LCD Display Is Provided For Programming Of The Parameters & Monitoring The Running Status Of The Traffic System.
  • Total Freedom Of Programming: There Are No Fixed Outputs Configured By Default For Any Particular Signal Outputs. The User Can Assign Any Output Numbers To The Desired Traffic Lights To His Convenience At The Site Of Operation.
  • Time Sync And Data Restoration: In Case Of Power Failure Or Restart Of The System, Data Will Be Restored And Signal Plan Timing Will Be Adjusted According To The Real Time
  • Erase Plan: User Can Erase Saved Data Of Individual Plans Or All Plans Together.
  • Flash Operation In Programming Mode: To Prevent The System From Complete Halt While In Programming Mode, User Can Switch The System Into Flash Mode Operation While Programing
  • Police Panel: Police Panel Is Provided To Allow The Traffic Police To Temporarily Disable The Auto Mode Operation And Operate The System In Manual Mode. A Push To On Switch Is Provided On The Police Panel To Manually Change The Signal Plan If Desired By The Police Personnel. All Output Lines Can Be Switched To On Or Off From Police
  • Panel For Maintenance Purpose While The Traffic Signal Controller Will Continue To Be In Active Mode.

 

Technical Specifications:-

  • Output Lines: 64 Output Lines (maximum)
  • Signal Plans: 64 Signal Plans
  • Cycle Plans: 24 Cycle Plans With 24 Entries On Each Plan
  • Day Plans: 7 Day Plans With 18 Entries Each
  • Week Plans: 7 Week Plans
  • Hurry Call: 8 Hurry Call Plans
  • Amber Plan: 16 Entries For Auto Changeover In Manual Mode
  • Line Test Plan: System Is Configured To Check Individual Output Lines
  • Erase Plan: Erase Individual Or All Plans Together
  • Plan Coordination: System Has The Capability To Be Coordinated With Multiple Units For Time Synchronization Using Gps Technology
  • Mode Of Operations: Auto / Manual / Flash / Hurry Call / Push / Lights On-Off
  • Operating System: Microcontroller Based Design
  • Led Switching: Solid State Switching
  • Working Voltage Of CPU: 5V DC
  • System: Microcontroller Based
  • Memory: 128k
  • Clock: Built-In RTC / GPS
  • Power Consumption (CPU): 5W Maximum
  • Operating Temperature: 0 To 55
  • Mode Of Operation: Stand-Alone & Synchronized
  • Signal Shut Down: Switch To Remove The Signal Light Source Supplies Without Interfering With The Supply To The Controller Operating Circuits
  • Enclosure: Powder Coated M.S Box With IP-65 Protection And Provision For Pole Mounting And Surface Mounting, Separate Locking For The Panel And Police Panel
  • Mains Power To Control Panel: 180 To 270 V AC, 50 Hz / 24V DC
  • Maximum Power Consumption Of The Controller: Approximately 300W Including The Power Of Traffic Light