Order Code: 24257783.2
Category: General Lab Equipment V
High level, high quality digital-analog trainer It should combine all essential functions of analog and digital experiment with removable breadboard, includes DC power supply, function generator, two pulse switches, 8 &O...
High level, high quality digital-analog trainer
It should combine all essential functions of analog and digital experiment with removable breadboard, includes DC power supply, function generator, two pulse switches, 8 Ω 0.5W speaker etc.
Solder-less bread board should be interconnected with tie points Nickel plated contact, fitted with all DIP sizes and all components with lead and solid wire. It can be changed and replaced for different purposes and can be connected with demonstration panel. Therefore, It is very convenient for both teachers and students
It should consist of Fixed DC output power supply of ±5V, ±12V @500mA
It should include Dual Variable DC output power supply,0~30V,0~-30V@500mA
It should consist of AC power supply of 5~0~5VAC,12~0~12VAC
Potentiometers of 1K Ω, 10KΩ should be included
It should consist of Function generator with following frequency range.
Frequency range : 1Hz~10Hz
10Hz~100Hz
100Hz~1KHz
1KHz~10KHz
10KHz~100KHz
It should consist of Amplitude with following readings
Sine wave output : 0~6Vpp variable@1Hz ~1MHz in step of 5
Triangle wave output : 0~6Vppvariable@1Hz ~300KHz in step of 5
Square wave output : 0~5Vpp variable@1Hz ~ 400KHz in step of 5
TTL mode output : 5V@1Hz~1MHz in step of 5
It should have Two digits of 7 segment LED display
Should have Two pulse switches to generate inverting and noninverting pulses supported with de-bounce elimination
It should provide Toggle switches and corresponding output point. When switch is set at “Down” position, the output is LO level, contrarily it is to be 'High' level while setting at “Up” position
Speaker of8 ohm/ 0.5W to be used for load is to be provided
It should consist Four channel adapterThe two banana sockets and BNC jacks suitable for the trainer to be connected with peripherals
It should consist Sixteen bit LED display Red LEDs should separate input terminals. The LED will be lighted upwheninput is at“High level”and it will be turned OFFwhenit isat“NoInput”or at “Lowlevel”
0pin, 28pin, 20pin ZIF sockets should be provided.
Additional Accessories:
100 MHz Dual Channel Digital Storage Oscilloscope
Bandwidth : 100 MHz
Channels : 2 + External
Display : 7 inch LCD Colour ( 320X240 resolution)
Acquisition Mode : Sample, Peak detect, Averaging
Sample rate (real time) : 1GSa/s
Input coupling : DC,AC
Probe attenuation factors : 1X, 10X
Horizontal system:Time base range : 2ns/div ~ 50s/div
Vertical system: Vertical sensitivity : 1mV/div ~ 20V/div
Single bandwidth : Full bandwidth
Rising time (typical on BNC) : ≤ 3.5 ns
Trigger
Trigger mode : Edge, Pulse, Video & Alternate
Measurement system
Automatic measurement : 15
Waveform math : Add, Subtract, Divide,and FFT
Voltage : 100 ~ 240 VAC, 50Hz, CAT II
Fuse : 1A, T class, 250V
ACCESSORIES : 1 pair of 1:1 (10:1) passive probe, USB cable,
Power cable, Instruction manual
Digital Multimeter
True RMS
6000 counts display
Large LCD display
Back light,
Foldable back stand
DC Voltage: 60mV / 600mV / 6V / 60V / 600V / 1000V ± (0.5% + 3D)
AC Voltage: 60mV / 600mV / 6V / 60V / 600V / 750V ± (1.0% + 3D)
DC Current: 60mA / 600mA / 6A / 10A ± (1.2% + 3D)
AC Current: 60mA / 600mA / 6A / 10A ± (1.5% + 3D)
Resistance 600? / 6k? / 60k? / 600k? / 6M? ± (0.5% + 5D) 60M? ± (1.5% + 3D)
DUAL CHANNEL DC POWER SUPPLY
Output Voltage & Current: 32V/5A.
Metering: 3 Digit DPM.
Meter Accuracy: ±3 counts.
Constant Voltage Mode:
Regulation:
Line: ±0.01% ±2mV for ±10% change in line output.
Load: ±0.01% ±2mV for load change from zero to full load.
Ripple & Noise: 1mV rms max. 20Hz - 20MHz.
Constant Current Mode:
Regulation:
Line: ±0.1% ±250µA for ±10% line change.
Load: ±0.1% ±250µA for change in output voltage from 0 Volts to maximum output voltage.
Ripple & Noise: 0.04% rms.
Mode Indication: LED indication for constant voltage / constant current operating mode.
Output Polarity: Floating w.r.t. ground.
Overload Protection: Automatic overload and short circuit protection. 3 MHz FUNCTION GENERATOR
Frequency Range: 0.3Hz to 3MHz
Frequency Stability: < 0.5% / hr or 0.8% / 24 hr at constant ambient temperature (medium position of frequency control) Waveform Characteristics Sinewave Distortion:
0.3 Hz - 100 kHz: max. 0.5 %
0.1MHz-0.3MHz: max. 1.5%
0.3 MHz - 3 MHz: max. 3%
Square Wave Rise time: typ.<40ns
Overshoot: <5%
Triangular non-linearity: <1% (up to 100KHz)
Trigger Output: Square Wave synchronous to signal output, TTL > 4 Vpp
Frequency Display Accuracy:
Up to 3 Hz: ± (1% + 3 D)
3 Hz - 3 MHz: ± (5 × 1/100000 + 1D)
Output: (short-circuit-proof)
Output Voltage: 10 Vpp into 50?, max. 20 Vpp open circuit